Data Sheet

2-7. Inrush Current
60A at 110 Vac At cold start, maximum load.
120A at 220 Vac At cold start, maximum load.
2-8. Line Regulation
This line regulation is less than ± 1%, of rated input voltage @ full load .
2-9. Hold Up Time
10 mSec., @ Normal line, with full load.
2-10. Rise Time
50 mSec.,@ 100-240VAC input, with full load from 10% to 90% of output voltage.
2-11. Turn-ON Time
The output voltage should rise to 90% of rated output voltage in less than 3 SEC.
from AC apply to 110Vac start up.
2-12. Harmonic Standard and Power Factor
The adapter complied with IEC 61000-3-2 class D harmonic standard while input power
over than 75W. The P.F. shall >0.95 @100Vac input and >0.9 @240Vac input.
3-0. Output Requirements
3-1. Output Voltage and Current
3-2. Load Regulation
3-3. Dynamic Load Regulation
±5% excursion for 50% - 100% or 100% - 50% load change of DC output at
any frequency up to 1KHz(duty 50%)
Output Voltage (Vdc) Current Min.(A) Current Max.(A)
+24V 0 5A
Voltage (Vdc) Tolerance (%) Voltage range(Vdc)
+24V +5/, -5 22.8V—25.2V