5-0. Environment
5-1 Temperature
a. Operating : 0 to 40
b. Storage : -20 to 85
5-2 Humidity
a. Operating : 10% to 90 %
b. Storage: 5% to 90 %
5-3 Altitude
From sea level to 5,000 Meter ( operation ) and 5,000 Meter ( non operation )
6-0. Safety
6-1. Hi-Pot Test
P->S: 3000Vac 2Sec 10mA;
L,N-->FG: 1800Vac 2Sec 10mA
6-2. Insulation Test
500Vdc, 3Sec. between primary and secondary circuit
IR should 50 M.
6-3. Leakage Current
250uA at 240Vac/50 Hz
6-4. Safety
UL, CUL, TUV, CB, CE, FCC, BSMI, CU, PSE, RCM, IRAM, CCC, EK
6-5. EMS
Items Specification Reference
Contact: ± 4KV
ESD
Air: ± 8KV
IEC 61000-4-2
RS
Frequency: 80~1000MHz
Field Strength: 3V/M80% AM(1KHz)
IEC 61000-4-3
EFT
± 1.0 KV on input AC power ports.
IEC 61000-4-4
Line to Line: ± 1KV (peak)
SURGE
Line to F.G : ± 2KV (peak)
IEC 61000-4-5