Data Sheet
2-8. Line Regulation
This line regulation is less than ± 1%, of rated input voltage @ full load .
2-9. Hold Up Time
≧ 10 mSec., @ Normal line, with full load.
2-10. Rise Time
≦50 mSec.,@ 100-240VAC input, with full load from 10% to 90% of output voltage.
2-11. Turn-ON Time
The output voltage should rise to 90% of rated output voltage in less than 3 SEC.
from AC apply to 110Vac start up.
2-12. Harmonic Standard and Power Factor
The adapter complied with IEC 61000-3-2 class D harmonic standard while input power
over than 75W. The P.F. shall >0.95 @100Vac input and >0.9 @240Vac input.
3-0. Output Requirements
3-1. Output Voltage and Current
3-2. Load Regulation
3-3. Dynamic Load Regulation
±5% excursion for 50% - 100% or 100% - 50% load change of DC output at
any frequency up to 1KHz(duty 50%)
3-4. Ripple & Noise
The power supply shall not exceed the following limits on the indicated voltage for 60Hz
or 50Hz ripple, Switching frequency ripple and noise and dynamic load variations
measured with a 20MHz bandwidth
Output Ripple/Noise
+12V
2.0% max. of rated output voltage
Output Voltage
(Vdc)
Current
Min.(A)
Current Max.(A)
+12V 0 10.0A
Voltage (Vdc) Tolerance (%) Voltage range(Vdc)
+12V
+5/,-5
11.4V — 12.6V