Data Sheet
5-0. Environment.
5-1 Temperature :
a. Operating : 0 to 40 ℃
b. Storage : -20 to 85 ℃
5-2 Humidity :
a. Operating : 10 to 90 %
b. Storage: 5 to 90 %
5-3 Altitude :
From sea level to 5,000 Meter (operation) and 5,000 Meters (non operation)
6-0. Safety
6-1. Hi-Pot Test
AC 3000V 10mA 2 Sec. between primary and secondary circuit.
AC 1800V 10mA 2 Sec. between L & N and FG.
6-2. Insulation Test
500Vdc 3sec. between primary and secondary circuit.
IR should ≧ 50MΩ
6-3. Leakage Current
≦ 750uA, at 240Vac/50Hz.
6-4. Safety
UL, CUL, TUV, CB, CE, FCC, BSMI, CCC, PSE, EK, BIS
6-5. EMS
Items Specification Reference
Contact:±4KV
ESD
Air:±8KV
IEC61000-4-2
RS
Frequency:80 ~ 1000MHz
Field Strength 3V/M,80% AM(1KHz)
IEC61000-4-3
EFT 1.0KV on input AC power ports. IEC61000-4-4
Line to Line:±1KV (peak)
SURGE
Line to FG:±2KV (peak)
IEC61000-4-5
6-6. EMI
Comply with Standards
CISPR32, EN55032 Class B
FCC PART 15 Class B