Data Sheet

2-8. Line Regulation:
This line regulation is less than
± 1%, 100Vac/60Hz-240Vac/50Hz, with Max. load.
2-9. Hold Up Time:
10mSec. @ 100Vac/60Hz-240Vac/50Hz, with Max. load.
2-10. Rise Time:
50mSec. @ 100Vac/60Hz-240Vac/50Hz, with Max. load.
From 10% to 90% of output voltage.
2-11. Turn-ON Time:
The output voltage should rise to 90% of rated output voltage.
in less than 3 SEC. 100Vac/60Hz-240Vac/50Hz, with Max. load.
2-12. Harmonic Standard and Power Factor
The adaptor complied with IEC61000-3-2 Class D harmonic standard while input power
over than 75W. The PF shall > 0.95 @ 100Vac input and > 0.9 @ 240Vac input with
Max. load.
3-0. Output Requirements
3-1. Output Voltage and Current
3-2. Combine Regulation
3-3. Dynamic Load Regulation
±5% excursion for 50% - 100% or 100% - 50% load change of DC output at
any frequency up to 1KHz(duty 50%)
3-4. Ripple
Noise
The power supply shall not exceed the following limits on the indicated voltage for 60Hz or
50Hz ripple,
Switching frequency ripple and noise and dynamic load variations measured with a 20MHz
Output Voltage
(Vdc)
Currnet
Min. (A)
Current
Max. (A)
+12V 0A 7.5A
Output Voltage
(Vdc)
Tolerance (%) Regulation (V)
12V
+5%~-5% 11.4V ~ 12.6V