Data Sheet
Table Of Contents
5-2 Humidity
a. Operating : 10 to 90 %
b. Storage: 5 to 90 %
5-3 Altitude
From sea level to 5,000 Meters ( operation ) and 5,000 Meters (no operation)
6-0. Safety
6-1. Hi-Pot Test
3000Vac/4242VDC, 3mA 2Sec. between primary and secondary circuit
L,N to FG 1800Vac 3mA 2Sec.
6-2. Insulation Test
500Vdc, 2 Sec. between primary and secondary circuit
IR should ≧ 50 MΩ.
6-3. Leakage Current
≦ 500 uA, at 240Vac/50 Hz
6-4. Safety
UL, CUL, TUV, CB, CE, FCC, BIS, EK, BSMI, PSE, CCC, RCM
6-5. EMS
Items Specification Reference
Contact: ± 4KV
ESD
Air: ± 8KV
IEC 61000-4-2
RS Frequency: 1KHz Field Strength: 3V/M IEC 61000-4-3
EFT 1.0 KV on input AC power ports. IEC 61000-4-4
Line to Line: ± 1KV (peak)
SURGE
Line to F.G : ± 2KV (peak)
IEC 61000-4-5
6-6. EMI
Comply with Standards
CISPR 32, EN 55032 Class B
FCC (PART 15 CLASS B)