Data Sheet
Table Of Contents
2-7. Inrush Current
≦ 60A at 110 Vac
≦ 120A at 220 Vac At cold start, maximum load.
2-8. Line Regulation
This line regulation is less than ± 1%, of rated output voltage @ full load .
2-9. Hold Up Time
≧ 8.3 mSec., @ Normal line, with full load.
2-10. Rise Time
≦50 mSec., @ 115V AC input, with full load.
From 10% to 90% of output voltage.
2-11. Turn-ON Time
The output voltage should rise to 90% of rated output voltage
in less than 3 SEC. from AC apply to 110Vac start up.
3-0. Output Requirements
3-1. Output Voltage and Current
3-2. Load Regulation
3-3. Dynamic Load Regulation
±5% excursion for 50% - 100% or 100% - 50% load change of DC output at
any frequency up to 1KHz(duty 50%)
3-4. Ripple & Noise
The power supply shall not exceed the following limits on the indicated voltage for 60Hz
or 50Hz ripple, Switching frequency ripple and noise and dynamic load variations
measured with a 20MHz bandwidth
Output Voltage
(Vdc)
Current
Min.(A)
Current Max.(A)
+12V 0 5.0A
Voltage (Vdc) Tolerance (%) Regulation (Vdc)
+12V +5/, -5 11.4~12.6V