6‐0. Safety
6‐1. Hi‐Pot Test
P‐>S: 3000Vac 2Sec 10mA;
6‐2. Insulation Test
500Vdc, 2Sec. between primary and secondary circuit
IR should ≧ 100 MΩ .
6‐3. Leakage Current
≦250uA at 240Vac/50 Hz
6‐4. Safety
UL, CUL, TUV, CB, CE, FCC, BSMI, CU, RCM, IRAM, CU
6‐5. EMS
Items Specification Reference
Contact: ± 4KV
ESD
Air: ± 8KV
IEC 61000‐4‐2
RS
Frequency: 80~1000MHz
Field Strength: 3V/M,80% AM(1KHz)
IEC 61000‐4‐3
EFT
1.0 KV on input AC power ports.
IEC 61000‐4‐4
SURGE
Line to Line: ± 1KV (peak)
IEC 61000‐4‐5
6‐6. EMI
Comply with Standards
CISPR 32, EN 55032 Class B
FCC PART 15 Class B
7‐0. Mechanical Characteristics
7‐1. Physical Size : 85.5 L x 35.7 W x 25.7 H (mm)
7‐2. Enclosure material : 94V‐0 minimum
7‐3. Output Cable (Reference) : UL1185 #16
7‐4. Vibration Test
The vibration frequencies are set at 20Hz, with total amplitude of 1.5mm
Along the 3 directions namely X‐Y‐Z. The each direction should be vibrated
for 60 minutes, after testing no abnormal electrical or mechanical should occur.