Data Sheet

60. Safety
61. HiPot Test
P>S: 3000Vac 2Sec 10mA;
62. Insulation Test
500Vdc, 2Sec. between primary and secondary circuit
IR should 100 MΩ .
63. Leakage Current
250uA at 240Vac/50 Hz
64. Safety
UL, CUL, TUV, CB, CE, FCC, BSMI, CU, RCM, IRAM, CU
65. EMS
Items Specification Reference
Contact: ± 4KV
ESD
Air: ± 8KV
IEC 6100042
RS
Frequency: 80~1000MHz
Field Strength: 3V/M80% AM(1KHz)
IEC 6100043
EFT
1.0 KV on input AC power ports.
IEC 6100044
SURGE
Line to Line: ± 1KV (peak)
IEC 6100045
66. EMI
Comply with Standards
CISPR 32, EN 55032 Class B
FCC PART 15 Class B
70. Mechanical Characteristics
71. Physical Size : 85.5 L x 35.7 W x 25.7 H (mm)
72. Enclosure material : 94V0 minimum
73. Output Cable (Reference) : UL1185 #16
74. Vibration Test
The vibration frequencies are set at 20Hz, with total amplitude of 1.5mm
Along the 3 directions namely XYZ. The each direction should be vibrated
for 60 minutes, after testing no abnormal electrical or mechanical should occur.