Data Sheet
3‐5. Over Voltage Protection
180% Max. of rated voltage.
The output voltage shall be shutdown and latch‐off when OVP occurred.
3‐6. Over Current Protection
110%‐200% of rated output current.
The adapter will enter protection at overload mode and no damage.
It will enter into normal condition if the fault condition is removed.
3‐7. Stability
2% Max. at constant load with constant input (after 30 minutes of operation).
3‐8.Temperature Rise
Less than 45℃ on top/bottom case at normal AC input & 80% load of DC output at
environment temperature 25℃.
3‐9. Drop‐out (Power Line Disturbance)
Output voltage shall remain within the specified regulation range, through the absence of
a line input during 1/2 cycle, at full load and normal AC line input
3‐10. Voltage Isolation
The DC ground will be isolated from the AC neutral and AC line.
4‐0.Reliability
4‐1. MTBF (MIL‐HDBK‐217F)
The power supply shall be designed and produced to have a mean time between failure
( MTBF) of 100,000 hours at 25 degrees C.
5‐0. Environment
5‐1 Temperature
a. Operating : 0 to 40 ℃
b. Storage : ‐20 to 85 ℃
5‐2 Humidity
a. Operating : 10 to 90 %
b. Storage: 5 to 90 %
5‐3 Altitude
From sea level to 5,000 Meter (operation ) and 5,000 Meter (non operation )