SUBJECT: SCOPE OF DOCUMENT CONTAINS : 1‐0. General Description 2‐0. Input Requirements 3‐0. Output Requirements 4‐0. Reliability 5‐0. Environment 6‐0. Safety 7‐0.
1-0. General Description The purpose of the document is to specify a Single phase AC input, single output switching power supply. This specification is suitable for: EA10442G Series This product is AC to DC switching power transfer device, it can provide for a 24V, 1.66A max & 40W max DC output with constant voltage source. This Specification defines the input, output, performance characteristics, environment, noise and safety requirement for a power supply. 2‐0. Input Requirements 2‐1.
2‐9. Hold Up Time ≧ 8.3 mSec., @ Normal line, with full load. 2‐10. Rise Time ≦50 mSec.,@ 100‐240VAC input, with full load from 10% to 90% of output voltage. 2‐11. Turn‐ON Time The output voltage should rise to 90% of rated output voltage in less than 3 SEC. from AC apply to 110Vac start up. 3‐0. Output Requirements 3‐1. Output Voltage and Current Output Voltage (Vdc) Current Min.(A) Current Max.(A) +24V 0 1.66A 3‐2. Load Regulation Voltage (Vdc) Tolerance (%) +24V +5/, ‐5 3‐3.
3‐5. Over Voltage Protection 180% Max. of rated voltage. The output voltage shall be shutdown and latch‐off when OVP occurred. 3‐6. Over Current Protection 110%‐200% of rated output current. The adapter will enter protection at overload mode and no damage. It will enter into normal condition if the fault condition is removed. 3‐7. Stability 2% Max. at constant load with constant input (after 30 minutes of operation). 3‐8.
6‐0. Safety 6‐1. Hi‐Pot Test P‐>S: 3000Vac 2Sec 10mA; 6‐2. Insulation Test 500Vdc, 2Sec. between primary and secondary circuit IR should ≧ 100 MΩ . 6‐3. Leakage Current ≦250uA at 240Vac/50 Hz 6‐4. Safety UL, CUL, TUV, CB, CE, FCC, BSMI, CU, RCM, IRAM, CU 6‐5. EMS Items Specification Reference Contact: ± 4KV ESD RS Air: ± 8KV Frequency: 80~1000MHz Field Strength: 3V/M,80% AM(1KHz) IEC 61000‐4‐2 IEC 61000‐4‐3 EFT 1.0 KV on input AC power ports.
7‐5. Drop Test (Referencing to CSA C22.2 No.950/UL1950/UL1310/EN62368) Products shall be dropped from a height of 1000 mm onto a horizontal surface consists of hardwood at 13mm thick , mounted on two layers of plywood each 19mm to 20mm thick , all supported on a concrete or equivalent non‐resilient floor.