Data Sheet
2-7. Inrush Current
≦ 40A
at 115 Vac
≦ 80A at 230 Vac At cold start, maximum load.
2-8. Line Regulation
This line regulation is less than ± 1%, of rated output voltage @ full load.
2-9. Hold Up Time
≧ 8.3mSec., @ Normal line, with full load.
2-10. Rise Time
≦50mSec., @ Rated AC input, with full load.
From 10% to 90% of output voltage.
2-11. Turn-ON Time
The output voltage should rise to 90% of rated output voltage
in less than 3 Sec. from AC apply to 100Vac from start up.
3-0. Output Requirements
3-1. Output Voltage and Current
3-2. Load Regulation
Voltage (Vdc) Tolerance (%) Regulation (Vdc)
+24V +5/, -5 22.8V~25.2V
3-3. Dynamic Load Regulation
±5% excursion for 50% - 100% or 100% - 50% load change of DC output at
any frequency up to 1KHz(duty 50%)
3-4. Ripple & Noise
The power supply shall not exceed the following limits on the indicated voltage for 60Hz
or 50Hz ripple, Switching frequency ripple and noise and dynamic load variations
measured with a 20MHz bandwidth
Output Voltage
(Vdc)
Current
Min.(A)
Current Max.(A)
+24V 0 1.0A