Data Sheet

4-0.Reliability
4-1. MTBF(MIL-HDBK-217F)
The power supply shall be designed and produced to have a mean time between
failure ( MTBF) of 100,000 hours at 25 degrees C
5-0. Environment
5-1 Temperature
a. Operating : 0 to 40
b. Storage : -20 to 85
5-2 Humidity
a. Operating : 10 to 90 %
b. Storage: 5 to 90 %
5-3 Altitude
From sea level to 5,000Meter ( operation ) and 5,000Meter ( non operation )
6-0. Safety
6-1. Hi-Pot Test
4242Vdc 10mA 2 second. between primary and secondary circuit
6-2. Insulation Test
500Vdc, 3 Sec. between primary and secondary circuit
IR should 50 M.
6-3. Leakage Current
250uA @ 240VAC 50Hz
6-4. Safety
TUV, CB, CE
6-5. EMS
Items Specification Reference
Contact: ± 4KV
ESD
Air: ± 8KV
IEC 61000-4-2
RS
Frequency:80~1000MHz
Field Strength: 3V/M80% AM(1KHz)
IEC 61000-4-3
EFT ±1.0 KV on input AC power ports. IEC 61000-4-4
SURGE Line to Line: ± 1KV (peak) IEC 61000-4-5