Specifications
SI-BM05
Ultrasound/High Frequency
2 Functions
- High Frequency
- Ultrasound
Machine Structure
Ultrasound Display
Ultrasound Indicator Light
Ultrasound Power
Ultrasound Down/Up
High Frequency
Indicator Light
High Frequency Power
Ultrasound Output
Ultrasound On/Off
Ultrasound Mode
Ultrasound Power
High Frequency Intensity
High Frequency Output
Ultrasound Probes
High Frequency Glass Tubes
Accessories Holder
High Frequency Handpiece
Operating Instructions for High Frequency Function
1. Connect the High Frequency handle's wire to the machine (it only
fits one way) making sure to fasten it into place the securing ring.
2. Simply insert the desired glass electrode (metal end first) into
the hole at the end of the handle.
3. Using the power switch, turn the machine to the “on” position and
the glass electrode should light up.
4. To control the intensity of the electrode, use the knob located at
the center of the face place labeled “Min/Max”. Turning this knob
allows the user to adjust the current to match the desired need.
5. When the machine is not in use, make sure the power switch is in
the “Off” position.
Operating Instruction for Ultrasonic function
I. Preparation
(1). Before start the ultrasonic, cleanse the area to be worked.
After cleansed, apply suitable lotion and gel to the skin.
(2). Press Power On/Off for Ultrasonic to start the function.
(3). Output intensity display on Intensity window, Press Intensity
“up” and “down” button to set output intensity, output intensity
classify into 9 levels, from minimum 0 to maximum 1.8 Watts/cm.
Each level is 0.2 Watts/cm. For Facial work, low to mid intensity
is recommended. For Body work, mid to maximum intensity
is recommended.
II. Face Treatment
(1). Connect Face Electrode (big one) into Face Electrode output.
(2). Press Intensity “up” and “down” button to set output
intensity to your need.
(3). Press Pulse/Continuing mode to select Pulse or Continuing
wave, Pulse/Continuing wave indicator will light on.
(4). Apply the Electrode working on the face.
III. Eye Treatment
(1). Connect Eye Electrode (small one) into Electrode output.
(Should take out the Face Electrode first)
(2). Press Intensity “up” and “down” button to set output
intensity to your need.
(3). Press Pulse/Continuing mode to select Pulse or Continuing
wave, Pulse/Continuing wave indicator will light on.
(4). Apply the Electrode working around the Eye area.
*** Important:
1. Clean skin with clear water.
2. Never stop the electrode on the skin in one spot.
3. Always keeps the electrode moving across the skin.
4. Never point the electrode towards chest area.
5. Do not immerse the handle or the machine into water.
6. Store in a dry cool place.
Safety Warning
1. When proceed deep cleaning or Galvanic,
accompanies with suitable emulsion or gel.
2. Do not modify the equipment.
3. Do not immerse the handle or the machine into water.
4. When adjust the intensity, slightly increase from low to max.
5. After usage, clean the accessories and store in a cool and
dry place. The machine should be grounding.
Specifications:
Voltage:
110V/60Hz □
Power: 22W
14 15