Operating Instructions and Installation Instructions
[
ECTIVE
®
SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
58
Safety features
☝ Please note!
Restart necessary!
The inverter is equipped with several safety features to protect the inverter and all its
components as for example the batteries.
The inverter is equipped with a thermic and electronic over-/undervoltage protection. If
the value is far below or far above the required limit, the device shuts itself down auto-
matically and has to be switched on again using the on/off button before its restart.
In the following situations the inverter shuts itself down automatically:
• internal temperature too high
• required output load too high
• input voltage too high or too low
Reason 12 V 24 V 48 V Action
risk of under-
voltage
10.8V±0.2V 21.6V±0.4V 43.2V±0.8V 2x acoustic signal
+ red LED flashing 2x
every 8 sec.,
inverter still working
total under-
voltage
10.2V±0.2V 20.4V±0.4V 40.8V±0.8V 3x acoustic signal
+ red LED flashes 3x
every 8 sec.,
automatic shutdown
overvoltage 15.5V±0.2V 31.0V±0.4V 62.0V±0.8V 4x acoustic signal
+ red LED flashing 4x
every 8 sec.,
automatic shutdown
overheating internal temperature >75°C 5x acoustic signal
+ red LED flashes 5x
every 8 sec.,
automatic shutdown
overload due
to powerful
consumers
regardless of the type red LED flashes con-
stantly until the error
is solved and device is
switched on again