Operating Instructions and Installation Instructions

[
ECTIVE
®
SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
58
Safety features
Please note!
Restart necessary!
The inverter is equipped with several safety features to protect the inverter and all its
components as for example the batteries.
The inverter is equipped with a thermic and electronic over-/undervoltage protection. If
the value is far below or far above the required limit, the device shuts itself down auto-
matically and has to be switched on again using the on/off button before its restart.
In the following situations the inverter shuts itself down automatically:
internal temperature too high
required output load too high
input voltage too high or too low
Reason 12 V 24 V 48 V Action
risk of under-
voltage
10.8V±0.2V 21.6V±0.4V 43.2V±0.8V 2x acoustic signal
+ red LED flashing 2x
every 8 sec.,
inverter still working
total under-
voltage
10.2V±0.2V 20.4V±0.4V 40.8V±0.8V 3x acoustic signal
+ red LED flashes 3x
every 8 sec.,
automatic shutdown
overvoltage 15.5V±0.2V 31.0V±0.4V 62.0V±0.8V 4x acoustic signal
+ red LED flashing 4x
every 8 sec.,
automatic shutdown
overheating internal temperature >75°C 5x acoustic signal
+ red LED flashes 5x
every 8 sec.,
automatic shutdown
overload due
to powerful
consumers
regardless of the type red LED flashes con-
stantly until the error
is solved and device is
switched on again