Operating Instructions and Installation Instructions
[
ECTIVE
®
SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
35
Explanation of symbols
ѥ Warning!
Failure to comply with these instructions could result in death or serious injury
⚠ Caution!
Failure to comply these instructions can cause functional impairment or damage of the
device.
☝ Please note!
Further information for the operation of the device.
Scope of supply
Number Designation Number Designation
1 Unit Inverter Set Suitable ATO fuse
1 Unit 230 V cold-device plug 1 Unit Operating instructions
Set Suitable battery cable
Contin-
uous
output
Model
SI-/TSI
Input
voltage
Battery cabel* Fuse/
Unit***
Battery
capacity**
300 W 32 12 V 4 mm², 1 set 35 A × 1 ≥50 Ah
34 24 V 2,5 mm², 1 set 20 A × 1 ≥25 Ah
38 48 V 2.5 mm², 1 set 10 A × 1 ≥12 Ah
500 W 52 12 V 6 mm², 1 set 35 A × 4 ≥100 Ah
54 24 V 4 mm², 1 set 20 A × 4 ≥50 Ah
58 48 V 2.5 mm², 1 set 10 A × 4 ≥25 Ah
1000 W 102 12 V 10 mm², 1 set 35 A × 4 ≥160 Ah
104 24 V 6 mm², 1 set 20 A × 4 ≥80 Ah
108 48 V 4 mm², 1 set 10 A × 4 ≥40 Ah