Operating Instructions and Installation Instructions

[
ECTIVE
®
SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
35
Explanation of symbols
ѥ Warning!
Failure to comply with these instructions could result in death or serious injury
Caution!
Failure to comply these instructions can cause functional impairment or damage of the
device.
Please note!
Further information for the operation of the device.
Scope of supply
Number Designation Number Designation
1 Unit Inverter Set Suitable ATO fuse
1 Unit 230 V cold-device plug 1 Unit Operating instructions
Set Suitable battery cable
Contin-
uous
output
Model
SI-/TSI
Input
voltage
Battery cabel* Fuse/
Unit***
Battery
capacity**
300 W 32 12 V 4 mm², 1 set 35 A × 1 50 Ah
34 24 V 2,5 mm², 1 set 20 A × 1 25 Ah
38 48 V 2.5 mm², 1 set 10 A × 1 12 Ah
500 W 52 12 V 6 mm², 1 set 35 A × 4 100 Ah
54 24 V 4 mm², 1 set 20 A × 4 50 Ah
58 48 V 2.5 mm², 1 set 10 A × 4 25 Ah
1000 W 102 12 V 10 mm², 1 set 35 A × 4 160 Ah
104 24 V 6 mm², 1 set 20 A × 4 80 Ah
108 48 V 4 mm², 1 set 10 A × 4 40 Ah