SDS

Safety Data Sheet
According to HCS-2012 APPENDIX D TO ยง1910.1200
Version: 1.0/EN
Revision date: 29/04/2015
Product name: Lithium-ion Battery
Issue date: 29/03/2016
Report No.: NCT16014434S1-1
5 / 9
8. Exposure controls/personal protection
(a)Control parameters
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Lithium Cobalt Oxide
(CoLiO2)
12190-79-3
TWA: 0.02 mg/m3
Aluminum
7429-90-5
TWA: 1 mg/m3
respirable fraction
TWA: 15 mg/m3 total dust
TWA: 5 mg/m3 respirable fraction
(vacated) TWA: 15 mg/m3 total
dust
(vacated) TWA: 5 mg/m3
respirable fraction (vacated)
TWA: 5 mg/m3 Al Aluminum
TWA: 10 mg/m3 total
dust
TWA: 5 mg/m3
respirable dust
Copper
7440-50-8
TWA: 0.2 mg/m3 fume
TWA: 1
mg/m3 Cu dust and mist
TWA: 0.1 mg/m3 fume
TWA: 1 mg/m3 dust and mist
(vacated) TWA: 0.1 mg/m3 Cu
dust, fume, mist
IDLH: 100 mg/m3 dust,
fume and mist
TWA: 1 mg/m3 dust
and mist
TWA: 0.1 mg/m3 fume
Phosphate(1-),
hexafluoro-, lithium
21324-40-3
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 dust
(vacated) TWA: 2.5 mg/m3
ACGIH TLV: American Conference of Governmental Industrial Hygienists -Threshold Limit Value
OSHA PEL: Occupational Safety and Health Administration - Permissible Exposure Limits Immediately Dangerous to
Life or Health
Other Exposure Guidelines: Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d
962(11th Cir., 1992) See section 15 for national exposure control parameters
(b) Appropriate engineering controls
Engineering Measures: 1.Showers
2.Eyewash stations
3.Ventilation systems
(c) Individual protection measures, such as personal protective equipment
Eye/Face Protection:
Not necessary under normal conditions, wear safety glasses if handling an open or
leaking battery.
Skin and body Protection:
Not necessary under normal conditions, Wear protective gloves and protective
clothing such as long sleeved clothing, impervious gloves, chemical resistant apron,