OWNER’S MANUAL How to install, operate and maintain your EcoWater Systems Air Aspirated Iron Filter Models ETF AIV-10 ETF AIV-12 Designed, Engineered & Assembled in the U.S.A. EcoWater Systems LLC P.O. Box 64420, St. Paul, MN 55164-0420 1-800-86WATER 7336313 (Rev.
ECOWATER Table of Contents S Y S T E M S TABLE OF CONTENTS Page Specifications & Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Inspect Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ECOWATER Specifications & Dimensions S Y S T E M S SPECIFICATIONS Model ETF AIV-10 Model ETF AIV-12 Amount of Zeolite Media 1.0 cu. ft. 2.0 cu. ft. Flow Rate 7 - 10 gpm 9 - 15 gpm Model Code HAAIF Amount of Quartz Gravel HAAIF 17 lbs. Minimum Backwash Flow Rate 7 gpm* Maximum Supply Water Pressure Water Temperature Limits (min./max.) Electrical Rating (transformer supplied) 29 lbs.
ECOWATER Inspect Shipment & Safety Guides S Y S T E M S INSPECT SHIPMENT The parts required to assemble and install the Air Aspirated Iron Filter are included with the unit. Thoroughly check the water filter for possible shipping damage and parts loss. Also inspect and note any damage to the shipping carton. Remove and discard (or recycle) all packing materials. To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them.
ECOWATER Before Starting Installation S Y S T E M S WHERE TO INSTALL THE FILTER TOOLS, PIPE & FITTINGS, OTHER MATERIALS YOU WILL NEED = Place the filter as close as possible to the pressure tank (well system) or water meter (city water). = Plastic inlet and outlet fittings included with the fil- ter allow water flow equivalent to 1 inch nominal pipe. To maintain full valve flow, 1” pipes to and from the filter fittings are recommended. Do not reduce the pipes to less than 3/4” size.
ECOWATER Typical Installation Illustrations S Y S T E M S INSTALLATION USING ECOWATER BYPASS VALVE Filtered Water OUT CROSS-OVER Use if water supply flows from the left. Include single or 3-valve bypass.
ECOWATER Installation S Y S T E M S 1. TURN OFF WATER SUPPLY Clip (2) a. Close the main water supply valve near the well pump or water meter. 1” Copper Tubes (install in filter valve or Turbine bypass valve) b. Shut off the electric or fuel supply to the water heater. OUTLET c. Open high and low faucets to drain all water from the house pipes. Support 2. INSTALL BYPASS VALVE AND/OR COPPER TUBES: a.
ECOWATER Installation S Y S T E M S b. Place bypass valve(s) into “bypass” position. On a single valve, slide the stem inward to BYPASS (See Fig. 4 on page 6). On a 3 valve system, close the inlet and outlet valves, and open the bypass valve (See Fig. 3 on page 6). Ground Clamp c. Fully open the house main water pipe shutoff valve. Observe a steady flow from both opened faucets. Inlet & Outlet Pipes d. Close both faucets. e. Check your plumbing work for leaks and, if any are found, fix right away.
ECOWATER Description of Operation & Sanitizing S Y S T E M S DESCRIPTION OF OPERATION Service water enters the filter and passes through air captured at the top of the mineral tank. Dissolved iron, manganese and sulphur are oxidized and then removed by the media in the tank. When the system recharges, it first backwashes the contaminants to the drain, then empties the tank of water, replacing it with air drawn through the aspirator.
ECOWATER Programming the Electronic Controller S Y S T E M S Display UP button DOWN button SELECT button RECHARGE button CONTROLLER SETTINGS REQUIRED FIG. 12 B. SET DAYS BETWEEN RECHARGES upon installation, and after an extended power outage. 1. If you completed the previous step, the word “RECHARGE" should show in the display (See Figure 15). Otherwise, press the SELECT button several times until it does.
ECOWATER S Y S T E M S Programming (continued) & Controller Features / Options C. SET RECHARGE START TIME 2. The filter’s default recharge start time is 12:00 AM. This is normally a time of day when water is not being used in the household. If you have a water softener or another filter installed, the recharge start times should be offset to assure adequate water flow and pressure.
ECOWATER Controller Features / Options (continued) S Y S T E M S RECHARGE CYCLE TIME ADJUSTMENTS AUXILIARY OUTPUT CONTROL The default setting for backwash and aspirate times of the recharge cycle are factory set for maximum performance of the filter. Use the following procedures to check for correct cycle times, or to change, if desired. It is recommended that only trained technicians should change the time settings.
ECOWATER S Y S T E M S Features / Options (continued) & Routine Maintenance Then press the SELECT button to display the screen shown in Fig. 24. FIG. 23 FIG. 24 4. CHEMICAL FEEDER TRIP VOLUME: If you have set the auxiliary output control to CF (Chemical Feeder), you will need to set the volume of water which must flow past the turbine before the auxiliary output is turned on. With the alternating screens in Fig. 23 shown, use the á UP or â DOWN buttons to set the trip volume, in gallons. 5.
ECOWATER Troubleshooting S Y S T E M S AUTOMATIC ELECTRONIC DIAGNOSTICS MANUALLY INITIATED ELECTRONIC DIAGNOSTICS This filter has a self-diagnostic function for the electrical system. The computer monitors electronic components and circuits for correct operation. If a malfunction occurs, an error code appears in the display. Use the following procedures to advance the filter through the recharge cycles to check operation.
ECOWATER Troubleshooting (continued) S Y S T E M S RESETTING TO FACTORY DEFAULTS 7. To return to the present time display, press the SELECT button. If the model code was changed, make all controller settings. To reset the electronic controller to its factory default for all settings (time, days between recharges, etc.
ECOWATER Troubleshooting Guide & Wiring Schematic S Y S T E M S PROBLEM Iron bleed TROUBLESHOOTING GUIDE CAUSE 1. Riser tube o-ring. 1. Reseat or replace riser o-ring. 3. Time clock set incorrectly. 3. Check and change time. 2. Over-running filter bed. 2. Increase recharge frequency and backwash time. 4. Increase in iron, hydrogen sulfide or manganese. 4. Increase recharge frequency and backwash time. 5.
ECOWATER Repair Parts S Y S T E M S FILTER EXPLODED VIEW FILTER PARTS LIST 1 19 Key No. 7210478 Top Cover 3 7259927 Wire Harness 4 2 5 3 ¢ 6 9 10 7 Valve Assembly See Pages 18 - 19 for parts 8 4 5 12 7 14 7308970 7211173 7274286 7211068 7211050 á – 7112963 11 á 13 á 15 16 16 7210509 9 14 15 7336363 7331177 12 6 13 7275907 – 10 11 Description 1 2 20 Part No.
ECOWATER Repair Parts S Y S T E M S VALVE EXPLODED VIEW 50 51 52 93 53 92 54 91 55 Flow Plug Assembly Assembled View 56 90 89 88 58 59 94 57 70 60 87 61 73 66 86 67 Wear Strip 85 62 Seal 84 Cross-section View 83 63 82 68 75 64 70 71 69 65 81 80 79 78 74 77 76 18 73 72
ECOWATER Repair Parts S Y S T E M S VALVE PARTS LIST Key No. Part No. 50 7224087 Screw, #8-32 x 1” (2 req.) 52 7231393 Motor Plate 51 53 54 55 56 57 58 59 7286039 0900857 7171250 7335024 7169180 7172793 7170288 7178202 7178210 – 7185487 61 á 60 62 63 64 65 á á á á á 66 7174313 68 7171187 67 7335058 69 7129889 71 7077642 70 72 7089306 7271204 Key No. Description 73 Motor (incl. 2 ea. of Key No.
ECOWATER Warranty S Y S T E M S LIMITED WARRANTY EcoWater Systems LLC Advantage Warranty Series ETF AIV Water System Congratulations! You have just purchased the highest quality water conditioning product on the market. To register your warranty, complete the enclosed Warranty Registration Card and mail it within 30 days of purchase.