Owner`s manual

39
ECOWATER
SYSTEMS
Specifications
Efficiency ratings are only valid at the lowest salt dosage and service flow rate. These units were efficiency rated according to
NSF/ANSI Standard 44.
Intermittent flow rate does not represent the maximum service flow rate used for determining the unit’s rated capacity and effi-
ciency. Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance.
The validity of these flow rates is verified by Water Quality Association (WQA).
Capacity to remove clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if
water supply contains greater than 5 ppm clear water iron.
Canada working pressure limits: 1.4 - 7.0 kg/cm².
These units conform to NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data.
ERR 3500R20 and ERR 3502R30 also conform to NSF/ANSI 42 for chlorine reduction as verified and substantiated
by test data from Water Quality Association (WQA).
ECR
3500R20
ERR
3500R20
ECR
3500R30
ECR
3502R30
ERR
3502R30
ECR
3502R40
ECR
3502R50S
ECR
3502R70
Model Code HR20 HR20+ HR30 2H30 2H30+ 2H40 2H50 2H70
Rated Softening Capacity
(Grains @ lb. Salt Dose)
5,700 @ 1.1
16,800
@ 4.3
20,400 @ 7.5
6,200 @ 1.1
17,400
@ 5.2
22,200 @ 8.9
8,300 @ 1.6
25,000
@ 6.4
30,200 @ 11.3
8,300 @ 1.6
25,000
@ 6.4
30,200 @ 11.3
7,500 @ 1.7
21,400
@ 6.4
27,500 @ 11.0
11,300 @ 2.2
33,200
@ 8.5
40,100 @ 14.8
23,000 @ 4.5
40,800
@ 9.9
47,900 @ 15.3
32,900 @ 6.2
57,600
@ 12.8
71,500 @ 19.3
Rated Efficiency (gr./lb. of
Salt at Min. Salt Dose)
5150 4440 5160 5160 4420 5150 5110 5310
Service Flow Rate (gpm)
9.0 9.0 11.0 11.0 10.0 12.0 20.0 12.0
Pressure Drop at Service
Flow Rate (psi)
10 8 8 8 8 13 15 11
Intermittent Flow Rate
(gpm) @ 15 psi
12.0 14.8 16.5 16.5 14.2 13.6 20.0 17.0
Intermittent Flow Rate
(gpm) @ 30 psi
19.4 23.6 25.8 25.8 21.4 21.6 30.0 22.0
Amount of High Capacity
Resin (cu. ft.)
0.60 0.71 0.89 0.89 0.88 1.18 1.53 2.05
Water Supply Max.
Hardness (gpg)
40 50 60 60 60 75 95 125
Water Supply Max. Clear
Water Iron (ppm)
10 10 12 12 12 15 15 15
Min.-Max. Working
Pressure (psi)
20 - 125
Min.-Max. Operating
Temperature (°F)
40 - 120
Min. Water Supply Flow
Rate (gpm)
3
Max. Flow Rate (gpm) to
Drain during Recharge
2.4 3.0 3.0 3.0 3.0 3.0 5.4 5.4