VIDO Installation Manual
5.0 Controls (continued...)
Installer’s Set-up Parameters
To access the installation parameters menu, scroll to AUTO (while
in full mode), then press (OK) for 10s. Use ( ) and ( )
keys to highlight the parameter to be adjusted. Press (OK) to toggle
the parameter setting, when the value starts to blink, use the (+)
and (-) keys to adjust the value. Then, press (OK) to confirm. Once
parameters are set, go to <End> parameter and press (OK) to go
back to the main menu.
06
EN
Program Mode
Built-in Program Selection
A quantity of 9 built-in (P1-P9) and 4 user defined (U1-U4) timed
program options are available to choose from. Each day is divided
into 24 one hour periods operating in either Comfort setting (21°C
default) or Night set-back setting (19°C default).
Scroll to the preferred program number P1-P9 (FIG 9, A) using the
(+) and (-) keys. The controls will then automatically go back to
AUTO mode.
Built-in programs description
P1 Morning, Evening & Weekend
P2 Morning, Afternoon, Evening
& Weekend
P3 Day & Weekend
P4 Evening & Weekend
P5 Morning, Evening
P6 Morning, Afternoon & Weekend
P7 7h-19h (Office)
P8 8h-19h, Saturday
P9 Weekend only
Parameter
Name
Default SettingDescription Alternative Setting
Select temperature scale.dEG °C °F
Select the hour format.00:00 12H 24H
The air pulse will operate 5 minutes on the 5 minutes off
to ensure effective air circulation in cooling.
AiPu YE5
(Yes)
NO
(No)
Selection of the number of valves to be driven.
This parameter depends on the system design.
Nb vAL
(2 Pipe
models only)
0 valve 1 valve
Allows the maximum fan speed to be switched off - the
unit will only run in Low and Medium speeds.
FAS SPEE FA5
For Fast
NEd
For Medium
Select option for fan speeds when the unit reverts to
night set back in cooling operation.
NIGt NOr
(For Normal regulation)
AL1
(Fan speed 1 only)
Reverts the control back to factory settings.CLr ALL Press (OK) for 5 seconds
Exit the installation menu.End Press (OK)
Heating set point.HSP The default water switching temperature for heating is
32°C, this can be altered by pressing (+) or (-) keys then
pressing (ok) to confirm.
Cooling set point.
CSP
The default water switching temperature for cooling
is 15°C, this can be altered by pressing (+) or (-) keys
then pressing (ok) to confirm.
Calibration of the internal air sensor against the actual
room temperature.
(The calibration must be done after 12 hours working at
the same set temperature).
AIr
(Air)
To adjust the air sensor temperature, enter the
measured temperature using the (-) or (+) keys.
To confirm the calibration, press (ok)
Press (+) and (-) keys at the same time to reset
the offset value.