installation manual
PANEL RADIATORS ECOSTYLE  5 
Note! 
The radiator must be connected as above.  
Faulty connections might cause a heat 
output decrease. 
O
PPOSITE ENDS CONNECTION
Top-bottom opposite ends connection
requires external supply and return valves.
The bottom connections are to be plugged.
SA
ME END CONNECTION 
Top-bottom same end connection requires
external supply and return valves. The bottom 
connections are to be plugged.
B
OTTOM CONNECTION
Thanks to the built in valve system, connection 
at the bottom is possible. Bottom right hand 
connection is standard, but the radiators are 
reversible so left hand connection
 is possible.
Connections
The integrated valve system is welded onto the 
radiator during the manufacturing process and is 
All Biasi 
Ecostyle radiators are equipped with a built 
in valve insert suitable for thermostatic sensor 
heads (purchased separately). 