Specification
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
1.1
1.7
2.4
3.7
5.0
5.6
7.5
POU 3.5 0.7
Model GPM Approx. Usage
Inlet Temp: 72°F
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
0.6
0.9
1.3
2.0
2.6
2.9
3.9
Model GPM Approx. Usage
Inlet Temp: 42°F
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
0.8
1.1
1.7
2.6
3.4
3.8
5.1
POU 3.5 0.5
Model GPM Approx. Usage
Inlet Temp: 57°F
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
1.0
1.4
2.1
3.2
4.3
4.9
6.5
POU 3.5 0.6
Model GPM Approx. Usage
Inlet Temp: 67°F
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
0.6
0.8
1.2
1.8
2.4
2.7
3.6
Model GPM Approx. Usage
Inlet Temp: 37°F
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
0.7
1.0
1.5
2.3
3.1
3.5
4.6
Model GPM Approx. Usage
Inlet Temp: 52°F
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
1.3
2.0
2.9
4.4
5.9
6.6
8.8
POU 3.5 0.9
Model GPM Approx. Usage
Inlet Temp: 77°F
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
0.6
0.9
1.4
2.1
2.8
3.2
4.2
Model GPM Approx. Usage
Inlet Temp: 47°F
POU 6
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
0.9
1.3
1.9
2.9
3.8
4.3
5.7
POU 3.5 0.6
Model GPM Approx. Usage
Inlet Temp: 62°F
Represents a hand sink 
faucet open with a ow of 
0.5 GPM
Represents a water-saver 
shower head open with a 
ow of 1.5 GPM
Results based on outlet 
temperature of 105°F and 
simultanerous operation of 
indicated xtures. Map shows 
general temperature zones, 
actual inlet temperature may 
be affected by local variations 
and seasonal changes.
Applications
Average gallons per minute (GPM) based 
on 2010 Plumbing Standards.
Water-Saver 
Shower Head
Standard 
Shower Head
Standard 
Hand Sink
Kitchen Sink
Bath Tub
1.5 GPM
2.0 GPM
0.5 GPM
1.0-2.0 GPM
≥ 4.0 GPM
2
Match your location on the map, shown above, to the corresponding chart below to determine unit capacity.
1
The EcoSmart tankless water heater you 
choose depends on your climate. Refer 
to this chart to nd out which model best 
suits your needs. 
42°F
57°F
37°F
52°F
47°F 72°F
67°F
77°F
62°F
3 Steps for Endless Hot Water
Model kW Volts Required Wire Required Breaker Max. Power Weight Dimensions
POU 3.5 3.5 120 10 AWG 30A 29 4.0 lb 6" x 11" x 3"
POU 6 5.5 220 10 AWG 30A DP 25 4.0 lb 6" x 11" x 3"
ECO 8 8 240 8 AWG 40A DP 33 4.8 lb 11.5" x 8" x 3.75"
ECO 11 11.8 220 6 AWG 60A DP 54 6.5 lb 11.5" x 8" x 3.75"
ECO 18 18 240 (2) 8 AWG (2) 40A DP 75 11.3 lb 17" x 14" x 3.75"
ECO 24 24 240 (3) 8 AWG (3) 40A DP 100 13.8 lb 17" x 17" x 3.75"
ECO 27  27 240 (3) 8 AWG (3) 40A DP 113 13.8 lb 17" x 17" x 3.75"
ECO 36  36 240 (4) 8 AWG (4) 40A DP 150 17.4 lb 17" x 21" x 3.75"
3
Check electrical specications and dimensions in the chart below.