Use and Care Manual
1. ON/OFF control: Press the ON/OFF control to turn the unit ON or OFF.
2. Operating Indicator: The indicator light has 3 states: (1) off when power is not
available, (2) flashing when power is available and unit is OFF, or when the
control panel is locked and the unit in ON, and (3) on when unit is ON.
3. UP and DOWN controls: Press and hold the UP and DOWN controls to set the
desired humidity level from 99% to 26% or select “CO” for continuous operation.
4. TIME control: Press to temporarily change the display to show current operating
hours and lifetime hours, based on minutes. For example, if the display shows “0000:
50”, it means the unit has operated for 50 minutes. To view current operating hours,
press the TIME control once. To view lifetime hours, press the TIME control twice.
To reset the current operating hours, turn the unit OFF or press and hold the TIME
button for 5 seconds. After 10000 hours of operation, the lifetime hours wraps
around to 0000:00.
5. Humidity and Time Display: The display has 3 modes: (1) off mode where the
display is blank when the unit is OFF, (2) humidity mode where the left 2 digits show
the desired humidity level and the right 2 digits show the environment humidity level,
and (3) time mode where the display shows current operating hours and lifetime hours.
After 10 seconds, the display reverts from time mode to humidity mode.
6. PURGE control: Press the PURGE control to manually initiate a pump purge
cycle. The pump will turn on for 40 seconds.
7. Purging Indicator: The indicator light turns on when the pump purge cycle is
active. The pump automatically initiates a pump purge cycle water when the reservoir
is full and when the unit is turned OFF.
8. Defrosting Indicator: The indicator turns on when the unit detects ice on the coil
and turns off when the ice has melted. During defrost, the blower pulls air from the
environment across the coil with the compressor turned off.
PAGE 7