COMMERCIAL HEPA AIR SCRUBBER CM US READ AND SAVE THESE INSTRUCTIONS OWNERS MANUAL
PAGE 2
PAGE 3
PRODUCT IDENTIFICATION 2 1 5 2 6 5 6 4 4 3 3 PA-45-LGR PA-70-LGR WARNING DO NOT OBSTRUCT THE AIR INLET OR OUTLET.
PAGE 5
The drainage hose must be positioned to be less than 15 ft. above the unit. Failure to do so may cause water backup in the pump resulting in leakage. PAGE 6 1. ON/OFF control 2. Operating Indicator 3. UP and DOWN humidity controls 4. TIME control 5. Humidity and Time Display 6. PURGE control 7. Purging Indicator 8.
1. ON/OFF control: Press the ON/OFF control to turn the unit ON or OFF. 2. Operating Indicator: The indicator light has 3 states: (1) off when power is not available, (2) flashing when power is available and unit is OFF, or when the control panel is locked and the unit in ON, and (3) on when unit is ON. 3. UP and DOWN controls: Press and hold the UP and DOWN controls to set the desired humidity level from 99% to 26% or select “CO” for continuous operation. 4.
A. Operations for general use: · To turn the unit ON, press the ON/OFF control. To protect the compressor, there is a 60 second startup delay when the unit is turned ON. · To set the desired humidity level, press and hold the UP and DOWN controls. · To turn the unit OFF, press the ON/OFF control. To drain any water in the pump reservoir, a pump purge cycle is automatically initiated when the unit is turned OFF. B.
Air Filter 1. Remove the air filter as shown above. 2. Vacuum any debris from the air filter. 3. Using luke-warm water and a mild detergent, wash the air filter and allow to dry. 4. Once dry, reinstall the air filter.
Maintenance REPLACING THE BATTERY I. II. III. IV. Remove the screws in the four corners of the control panel. Once the screws are removed, carefully lift the control panel to access the PCB. Refit the control panel onto the PCB. Refit the four screws.
CODE E1 E2 E3 E4 ERROR FLASHES EVERY 30 SEC’S HUMIDITY SENSOR ERROR LOW OR NO REFRIGERANT WATER PUMP FAULT OR BLOCKAGE FLASHES EVERY 30 SEC’S FLASHES EVERY 30 SEC’S FLASHES CONTINUALLY FLASHES CONTINUALLY MESSAGE DISPLAY READING TIMED DEFROST MODE. 50% R.H DISPLAYED TURN POWER OFF. DEHUMIDIFIER WILL TURN OFF THE DEHUMIDIFIER IS CONTINUOUS MODE IN OPERATION THEN TURN ON AGAIN. AUTOMATICALLY. THE FAULE MUST REASON WORKING CORRECTLY. BE RECTIFIED BEFORE OPERATION CAN COMMENCE.
1-YEAR WARRANTY PAGE 12
SPECIFICATIONS MODEL PA-45-LGR PA-70-LGR POWER SUPPLY 115V/60Hz 115V/60Hz WATER REMOVAL @ SATURATED (90°F, 90% RH) 145 PINTS PER DAY 125 PINTS PER DAY WATER REMOVAL @ AHAM (80°F, 60% RH) 85 PINTS PER DAY 77 PINTS PER DAY RATED POWER 460W 810W RATED CURRENT 4.2A 8.
21 19 20 2 18 17 26 25 12 16 14 28 15 13 8 27 6 3 29 11 5 4 1 7 29 9 29 7 10 23 22 24 ITEM NUMBER PART NUMBER DESCRIPTION QTY ITEM NUMBER PART NUMBER DESCRIPTION QTY 1 LGR45-01 INLET AIR DAMPER 1 16 LGR45-16 AC MOTOR 1 2 LGR45-02 SPONGE FILTER 1 17 LGR45-17 FAN BLADE 1 3 LGR45-03 INLET AIR DAMPER 1 18 LGR45-18 FAN BLADE 1 4 LGR45-04 TEMPERATURE SENSOR 1 19 LGR45-19 GUIDE PLATE 1 5 LGR45-05 EVAPORATOR 1 20 LGR45-20 AIR OUTLET NET COVER 1 6 LGR45
22 21 18 32 30 19 34 20 33 27 31 28 29 27 17 26 16 25 13 25 12 35 11 3 10 15 24 39 2 38 14 6 1 23 38 5 9 8 37 37 36 36 4 7 ITEM NUMBER PART NUMBER DESCRIPTION QTY ITEM NUMBER PART NUMBER DESCRIPTION QTY 1 LGR70-01 INLET AIR DAMPER 1 21 LGR70-21 VOLUTE CASING 1 2 LGR70-02 SPONGE FILTER 1 22 LGR70-22 AC MOTOR 1 3 LGR70-03 FRONT CASING 1 23 LGR70-23 FOUR WAY VALVE / BRASS 1 4 LGR70-04 FRONT CHASSIS 1 24 LGR70-24 REAR CASING 1 5 LGR70-05 WATER PUMP 1