65-00085-003 REV 1203 Breeze SP-ENG OM 12_03
Advanced Technology Electronic Air Quality System CONTENTS: Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Notable Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Principles of Operation . . . . . . . . .
APPLICATIONS Eliminates • Smoke • Odors • Tobacco Smoke Plus it works as an appliance to Sanitize an area to reduce: • Mold • Mildew • Bacteria NOTABLE FEATURES: • Remote Control • Variable Speed Fan • Sanitization Function • Adjustable Purification Control • Balanced Ion Production SPECIFICATIONS: Electrical: • 100 volt 50/60 hz, 110 volt 60 hz, 220 volt 50 hz, or 240 volt 50hz ac line operation depending on model • 30 watts power consumption • 24 to 30 KV, 20-30 Khz ion generation pulsator • Fixed
PRINCIPLES OF OPERATION Nature cleanses the air with the lightning and rain. Lightning produces ozone, as well as positive and negative ions which cleanse the air naturally. Rain helps bring the ozone and ions closer to the earth's surface. They are then attracted to atmospheric contaminants that are either removed from the air and attached to grounded objects or are oxidized. Breeze AT reproduces the natural conditions found in the outdoors. It is not designed to create an artificial environment.
Breeze AT Unit Features Purification Level / Sanitizer Indicator Lights Access Panel / Washable Filter Manual Controls Power / Ionizer Indicator Light Computer Style Power Cord Infrared Window and Remote Operation Indicator Fuse Main Power Switch • Uses Standard 100, 110, 220 or 240 volt household current depending on model • No Chemicals Necessary • Carbon-impregnated lint screen • Washable Ecotech Purification Plate • Low Maintenance • Variable Speed Fan • Adjustable Purifier control • Remote Co
Breeze AT Manual Controls POWER ON/OFF Fan DOWN Fan UP Purifier ON/OFF Sanitizer Purifier UP Purifier DOWN Removing the Rear Lint Screen 1 2 CAUTION: UNPLUG UNIT BEFORE SERVICING. NOTE: 110V MODEL DOES NOT USE LINT SCREEN CLIP - SKIP TO STEP 3 FOR MODELS WITHOUT CLIP. 1. Loosen 2 screws securing clip at top center of lint screen. 2. Slide clip up. 3 3. Gently pull top of lint screen out of unit. 4. Once the top is out of the unit, pick straight up on the lint screen to remove. 5.
ECOTECH PURIFIER PLATE INSTALLATION The Breeze AT utilizes one Ecotech purifier plate. Installation is as follows: 1. Unplug the Breeze AT. 2. Remove the rear filter door (see previous page). 3. Fully insert the purifier plate between the guides until it stops. 4. Replace the filter door. WARNING: DO NOT OPERATE the Breeze AT without the Rear Access / Filter Door installed correctly. PLACING THE UNIT Place the unit as high as possible to insure complete purification.
SETTING AND ADJUSTING CONTROLS WITH THE REMOTE TURNING YOUR BREEZE ON & OFF The Breeze AT will come on by pressing the POWER button on the remote. To turn on the Purifier feature, press the Purifier On/Off button once. To turn the Purifier feature off, press the Purifier On/Off again. 1. REMOTE FAN CONTROL The remote will set the fan by pressing the FAN UP or FAN DOWN button. To turn the fan off, press the POWER button (turns unit off as well).
Proper Purifier Level Settings for Indicated Square Footage square feet (square meters) approx. % output indicator lights lit 0 - 500 ( 0 - 46) 0- 20% 1 500 - 1000 (46 - 93) 20% - 40% 2 1000 - 1500 (93 - 139) 40% - 60% 3 1500 - 2000 (139 - 186) 60% - 80% 4 2000 - 2500 (186 - 232) 80% - 100% 5 NOTES ABOUT ADJUSTING THE PURIFICATION LEVELS The lights on the front of the Breeze AT indicate the approximate level of purifier output.
MAINTENANCE Periodic maintenance is required to insure that the Breeze AT operates properly. A severely polluted environment can foul a purifier plate in as little as two weeks, normal plate cleaning should take place monthly. Shown here are basic procedures that should be carried out to keep your unit running at top performance. CAUTION: Unplug the Breeze AT before performing any maintenance procedures. Cleaning the Case: Wipe the Breeze AT with a soft cloth dampened with water.
TROUBLESHOOTING Indicators of Operation The Ionizer/Fan lamp should be illuminated whenever the unit is on. Depending on the current Purifier setting, between 1 and 5 of the small blue purifier lights should be illuminated. The SANITIZER light should be RED when the sanitizing feature is on. A small lamp or bulb is located at the base of the frequency type ionizer antenna. Turn the unit on and check that the lamp is illuminated.
• Symptom: A strong odor of ozone is present within the environment. Problem: Too much ozone accumulation within the environment, as a result of improper purifier control setting, and / or lack of air movement. • Symptom: Visual haze of smoke and / or particulate remain within the environment. Problem: Lack of ionization and / or air movement. 6.