Manual
Hard
Water
Conditioned
Water
Floor Drain
Salt Storage Tank
Overflow Hose*
1--- 1/2” Airgap
INLET
OUTLET
Valve
Drain
Hose*
Single
Bypass Valve
Transformer
To Timer
3/4” coupling
3/4” pipe and fittings
Copper tube
Gasket & Nut
Bypass valve
Clips
To Outside
Facets
*Do not tee these
drain lines together
3/4” pipe
3/4” coupling
Copper tube
Nut
Gasket
9
Miracle Water Installation & Operation Manual
Planning Installation
Inlet - Outlet Plumbing Options
•  ALWAYS  INSTALL either  a  single  bypass  valve  (included)  or  a  3  valve  bypass  system  (not
included). Bypass valves allow you to turn off water to the softener for repairs if needed, but still
have water in house pipes. 
• Use 3/4” (minimum) pipe and fittings. 
• Use sweat copper... or, threaded pipe... or, PVC plastic pipe... or, other approved plumbing. 
Tie or wire valve drain hose in place, to keep over
floor drain.
NOTE:  Air gap requirements on Fig. 2
NOTE:  Salt Hole and Faceplate cover not
shown for clarity of drawing.
NOTE:  The bypass valve allows the water to
be turned off to the softener for
servicing, but still have water in the
house pipes.
Figure 2
MAIN WATER PIPE