Step G - Sanitize, Test and Purge System
SANITIZE THE SYSTEM 
Sanitizing is recommended immediately after installa-
tion of the Reverse Osmosis system. It’s also recom-
mended after servicing inner parts. It is important that 
the person installing or servicing the system have 
clean hands while handling inner parts of the system. 
Complete the following steps to sanitize the system.  
See Fig. 25. 
1. Make sure that the water supply to the Reverse 
Osmosis system is off. 
2. Open the Reverse Osmosis faucet. If the tank is 
not already empty, allow the water to empty. 
3. Locate the eyedropper included in parts bag and 
common household bleach (5.25%).  
4. Add 3 ml. of bleach into open end of yellow tubing. 
Handle bleach according to bleach manufacturer’s 
recommendations. See Fig. 25. 
5. Connect yellow tubing to tank connector. See Figs. 
14 and 25.  
6. Sanitizing the system will be completed during the 
pressure test and purging steps on the following 
page.  
NOTE: The bleach must be removed from the 
system before drinking the water. See purging 
instructions on the next page. 
FIG. 25