INLINE APPLICATIONS:
This pump is designed to operate in a system without being submerged in water.
CAUTION: This pump is not self-priming, which requires it to be filled with water and slightly
lower than the water level in a reservoir, tank, pond or aquarium. If plug drops into water, power
supply should be turned off to avoid electric shock. Pump can be used indoors or outdoors.
Supply cord cannot be changed or replaced. It cannot be bent or used to carry the pump.
If cord is damaged, do not use pump.
Basic Setup:
1. Make sure your pump is sized correctly for the volume of water to be moved and that it can
safely and effectively operate in your system.
To 120V AC
Outflow Tubing
Outflow Fitting
OUTFLOW
INFLOW
Strainer
Filter
Cover
Power
Cord
EXAMPLE 1: Typical Submersible Application
Pump fully submerged between 6 inches to 3 feet below water surface and secured to bottom or
side of reservoir or tank. Pump operates with the Strainer, Filter and Cover installed.
EXAMPLE 2: Submersible Application with Bottom Draw
Pump fully submerged between 6 inches to 3 feet below water surface and secured to BOTTOM
ONLY of reservoir or tank. Pump operates with Bottom Draw Adapter replacing the Strainer, Filter
and Cover.
Outflow Tubing
Outflow Fitting
Bottom Draw Adapter
OUTFLOW
INFLOW
NOTE: Never allow water
level to drop below the
Bottom Draw Adapter’s
intake to avoid running
the pump dry!
To 120V AC
Power Cord
2. Place pump in desired location, ensuring that the pump will operate at a slightly lower level
than your water source.
3. Install inflow and outflow fittings onto the pump that are appropriate for your application and
that correctly fit any tubing connected to them.
4. Install a connection on your water source using appropriately sized fittings.
5. Install tubing on all connections, making sure the inner diameter of the tubing matches the
outside diameter of the fittings installed.
6. Double check to make sure that all connections are secure.
7. Fill your system with water.
8. Connect the pump’s grounded power plug to a grounded electrical outlet.
4