Technical information

TC33 Temperature Controller
1/16 DIN Series
TC33 Operator’s Manual
Manual Rev. 2.2
Firmware Version 1.4x
Table of Contents
TC33
Description Page
1/16 DIN - PID Autotune
1. Main Features
…………………..…………………………………….… 3
Temperature Controller
2. Specifications
………………………...……….……………….……….. 3
Input ………..………………………………………………..…….. 4
PID Control …….…………………….…………………..….…….. 4
Output ……….….…………………………………..……………... 4
2.1 Main Dimensions
……..…………………………………..…….…... 4
1. MAIN FEATURES
3. Operation
.…………….…………………………………...……………. 5
Temperature multi-sensor input without hardware change.
3.1 General Electrical Connections
……………………………………6
Accepts thermocouples J, K, S, T, N, E, R, and RTD-Pt100.
3.2 Power Wiring
………………………………………..………………. 6
Dual Display: PV (red) and SV (green).
3.3 Input Wiring
…………………………..………………………………7
Selectable ºF/ºC temperature.
3.4 Standard Relay Outputs …………….………..…………….………7
RTD-Pt100 with 1º temperature resolution: -328 to 986
ºF (-200 to 530
ºC), and
0.1º temperature resolution: -199.9 to 986.0
ºF (-199.9 to 530.0
ºC).
3.5 Sourcing 4-20mA Output Wiring ……..……..……………………..7
3.6 Panel Assembly …….…..…………………………………….……..8
Input sample rate: 10 reading per second (100 ms).
3.7 Error Messages
…..………………………………………….………8
Isolated 4 to 20mA linear control output, optional.
4. Menu System
……………………………………………………………...8
Ramp and Soak: one controlled ramp and one timed soak are standard.
4.1 Initial Startup ……………...…………………………………….……9
Auto-tuning PID control, or manual PID control, or ON/OFF control with
hysteresis adjust.
4.2 Set Up Cycle Parameters …..…………...……………………….…9
Cycle Menu ………………………..…………………………..…..9
4.3 Digital Serial Number Access
…..…………………………….…….9
Sensor break protection in any condition.
Independent alarm hysteresis adjust.
Easy-to-set programming menu.
5. Configuration
……………..………………………………………..…….. 10
Firmware version displayed during power up.
5.1 Cycle 1 – Operation …..……………………………………………..10
Digital serial number.
Ramp & Soak
……………………………….……………….…….11
High impact ABS enclosure.
5.2 Cycle 2 – Tuning & Alarms ……..……….………...………………..12
Dimensions: 48x48x106mm.
5.3 Cycle 3 – Input Configuration …...………………………………….13
Power: 90 to 260Vac, 50/60Hz.
Alarms Configuration …….…………….…………….……………13
Table 1 – Alarm Functions
….……………………….….…..……14
5.4 Cycle 4 – Calibration
…………..……….…………………………...16
5.5 PID Auto-Tune Operation
………...…….………………………...…17
2. SPECIFICATIONS
5.6 PID Manual Tuning
………………………………………………….18
Table 2 – PID Manual Tuning
….………………………………..19
Dimensions: 48 x 48 x 106mm (1/16 DIN) Approximate weight: 200g max.
Panel cut-out: 45.5 x 45.5mm (± 0.3mm)
Quick PID Set Up Reference
…………………………………..……....…. 19
Terminal connection: screws, accepting 16 to 24 AWG wires or 6.3 mm fork
lugs.
Notes
……………………………………………..…………… ……………...21
Power: 90 to 260Vac, 50/60Hz, Consumption: 7VA max.
Configuration Sheet
………………………………………………………... 22
Operating environment: 0 to 50°C (32 to 122°F), humidity: 10 to 85% RH, non-
condensing.
Flame-Retardant ABS Plastic Case.
Warm-up time: 15 minutes max.
2 3