Specifications
FREE STANDING INSTALLATION
In the freestanding, or stand-alone system, the ECONOBURN™ boiler is the sole source of cen-
tral heating. In this system connect the piping as you would for any conventional hydronic heating
system (using zone valves, circulator zoning, or single zone ow check system).
The boiler must not be installed as a gravity system, as the controls are not designed for this type
of operation.
WIRING
The boiler main power tie-in is located on the back of the boiler, a 15 Amp 120V dedicated circuit
is recommended.
WARNING - ALL ELECTRICAL WIRING MUST CONFORM TO NA-
TIONAL AND LOCAL CODES.
INSTALLER INSTRUCTIONS TO THE BOILER OWNER
1. Keep area around unit clean.
2. Use SOLID wood only. Hardwood is preferred.
3. Load carefully. Plan wood load based on BTU requirement. Maintain intense burns for
maximum efciency.
4. Remove ash regularly as directed.
5. Watch for soot build up in Flue pipe, and Heat Exchanger.
6. Realize the danger of extreme overheating due to over ring.
7. Danger of ue re if poor maintenance produces creosote buildup.
8. Operation of unit during power failure, (i.e. manual operation of zone valves and ow check
valves).
9. When shutting down for extended periods, clean unit thoroughly.
10. BEFORE RELOADING THE BOILER WITH WOOD, DRAFT CONTROL FAN MUST BE
STOPPED, AND FLUE DAMPER FULLY OPENED FOR AT LEAST ONE MINUTE BEFORE
OPENING THE LOADING DOOR TO REFUEL.
This is necessary to ensure that smoke and ames from the re will not exit the loading door and
harm the operator.
12