User Start Guide
EVC200 Quick Start Guide
Specifications
• The EVC200 can be included with, and controlled, using any compatible Z-Wave controller. The EVC200 also acts as signal repeater for the Z-
Wave network, extending the Z-Wave transmission as part of the “mesh network”. The EVC200 is designed to work with a pre-installed
standard levered ball type water shut off valve. If your water shut off valve is not a levered type, consult a plumber to have your shut off
valve changed to a levered type.
• The EVC200 is designed to be installed onto an existing levered type ball valve as detailed below. Caution: If you do not have experience
installing and configuring EVC200 type devices, please consult a professional installer.
• Z-Wave Plus Certified
• Open/Closed toggle Button/Green LED indicator
• U.S. Standard Z-Wave Frequency
• Supported Valve Sizes: ½”, ¾”, 1" (Optional 1.25" and 1.5")
• Requires 12V DC/1amp power, AC Adapter Included
• Wireless Range: 30M (line of sight)
• Close/Open Time: ~ 18 seconds
• High Torque Geared Valve Motor: ~ 11lbf (~15Nm)
• Male 6 pin PS2 connector (cable 38"/980mm)
• Universal AC Adapter Included (cable length 48"/1230mm)
• Note: Requires Z-Wave Controller or Gateway
• Optional Plug-In Wired Leak Sensor
• Optional Output for second "slave" Valve Robot, see Condo Kits
• Optional Integrated Ball Valve
Including the EVC200 Z-Wave Automatic Valve with a Z-Wave Controller
Including or Adding the EVC200 to a Z-Wave Controller: Place the Z-Wave controller in inclusion (learning) mode. Press the Power button 3
or more times rapidly (within 0.5 seconds). Once the controller has acknowledged the inclusion, the EVC200 has been included in the Z-Wave
network with the controller. Exit the including mode and you should see the EVC200 Automatic Valve under your list of devices. Some devices
(like the Vera controller) require that you reload or refresh the controller so it polls, identifies, and configures the new device. Once the
configuration is complete, you can control the powered valve through your Z-Wave controller’s user interface. The valve supports Open or On
command and Closed or Off command through a standard Z-Wave controller. The valve can also be open or closed with a single push of the
power button on the unit, toggling from open to closed or closed to open. The valve can also be open/closed manually by hand by pushing
the clutch pin.
Excluding or Removing the EVC200 from a Z-Wave Controller: Place your Z-Wave controller in exclusion (un-learning) mode. Once the
controller is in exclusion mode, bring the EVC200 close to the Z-Wave controller (several feet) and press the Power button 3 or more times
rapidly (within 0.5 seconds). Once the controller has acknowledged the exclusion, the EVC200 has been cleared of any previous inclusions. (It
is recommended to keep the EVC200 within 1M/3ft of the controller when including or removing)
There can be a number of reasons that the EVC200 does not work with your controller. If the inclusion process does not work the first time,
repeat the process but try “excluding” first and then complete the “inclusion” process.
Motor Assembly
Control Module
Mounting Bracket
Silicone Tape
AC Adapter
(12V DC)
Valve Lever
pins
Pivot Point
Clutch Pin
Mounting Tab