V. Cleaning
1. Turn OFF heater and pump, let cool.
2. Lift basin out of reservoir and set on top of reservoir.
3. Disconnect the cam coupler on the hose and place the
basin on the ground.
4. Place hose from the pump over the side of the reservoir
and into the container being used to hold the waste fluid.
5. Turn ON the pump and pump the fluid level down to the
point where the pump quits pumping.
6. Evacuate the balance of the fluid in the bottom of the
reservoir.
7. Clean the excess residue from the bottom of the reservoir.
8. Clean any scale build up off the heater and thermowell
tube with a wire brush.
9. Refill unit with proper amount of fluid.
10. Reinstall the basin and reconnect the cam coupler.
11. Turn ON the heater and the pump and check for proper operation.
VI. Parts Breakdown
1 FLO-THRU BRUSH ....................................................................................................... 8169
2 FLEX HOSE .................................................................................................................. 13-10164-01
3 VALVE ........................................................................................................................... 13-10164-02
4 STRAINER, FILTER ...................................................................................................... 04397
5 BASKET STRAINER ..................................................................................................... 16-10176
6 DOOR CLOSURE .......................................................................................................... 02-10698-150
7 FUSIBLE LINK ............................................................................................................... 01178
8 FILTER BRACKET ........................................................................................................ 192097
9 FILTER .......................................................................................................................... 16-10194
10 FILTER HOUSING ......................................................................................................... 16-10166
11 HEATER ........................................................................................................................ 12-10208
12 PUMP ............................................................................................................................ 8870
13 POWER CORD.............................................................................................................. 12-10146
14 SWITCH ROCKER ........................................................................................................ 12-11143
15 LIQUID LEVEL SENSOR .............................................................................................. 16-10211
16 THERMOSTAT .............................................................................................................. 12-10149