Product Manual

04379 Page 5 11-01-12
ECN 3783
3. INHALATION (Breathing): Prolonged exposure to concentrate-mist or vapor may cause mild
irritation of nasal passages or throat. Remove to fresh air immediately. Do not leave victim
unattended. Get medical attention if irritation persists.
4. INGESTION (Swallowing): (Uncontaminated cleaning solution) Drink 4 to 8 ounces of water
and seek medical attention. DO NOT induce vomiting.
E. Environmental
1. Avoid spilling solution. Spilled solution can create slippery conditions, clean it up immediately.
Close off area to traffic. Wear appropriate personal protective equipment to prevent eye and skin
contact. Consult the Material Safety Data Sheet for instructions on clean up and disposal.
2. Contain leaks promptly. Notify local environmental authorities if necessary.
3. Aqueous solutions, when used to clean grease and oil, must be disposed of properly.
Consult your local environmental management agency for additional guidance and other
potentially hazardous materials compliance requirements.
4. For further information consult the Material Safety Data Sheet provided by the solution
supplier.
III. Installation
1. Position reservoir on a hard, level surface in a well-ventilated area. Place the basin on the
reservoir.
2. Fill solution reservoir to the correct level. This equipment is designed for use only with Aqueous
Based Solutions. Do NOT add any other chemicals to the cleaning agent including, but not limited
to, kerosene, fuel oil, gasoline, or chlorinated solutions. The use of any other solutions could
potentially cause a hazardous condition.
Capacity Model EM6000 = 45 gal. (170.3 L.)
Low Level = 35 gal. (132.5 L.)
3. Plug the power cord into a properly grounded power source. Check serial plate for power
requirements.
Power Requirements = 15 amp, 115 volt, 60 Hz