User manual

5. Managing DE Devices using MC Toolkit Software
5.7. Offline Configuration
Revision 12 MC Toolkit User Manual 111
May 2013
Download Parameter List
The table below lists all the Parameters available+ in the MC Toolkit offline configuration file
Index (Index of the
parameters in the
configuration file)
Parameters Example Values
Properties (R – Read
only; R/W – Read / Write)
0 Bus Type DE R
1 Device STT 3000 R
2 Tag ID STT250Ta R/W
3 Serial Number B044929237 R
4 Manufacturer Honeywell R
5 Model Number 2.0 R
6
Transfer Function (in ST
devices) Linearization in STT
devices)
ST:
Linear and Square root
STT:
Linear and Non-Linear
R/W
7 LRV 36.98 R/W
8 URV 594.63 R/W
9 PV Units 0 R/W
10 Output Range : Out Low 4
R – not displayed on the
screen
11 Output Range : Output High 20
R – not displayed on the
screen
12 Output Range : Out Units ma
R – not displayed on the
screen
13 OEM-Device Type Code
23-STT25M-S, v1.5-T, v0
(DE)
R – Not Displayed
14 LRL -200 R
15 URL 850 R
16 Damping 1.0 R/W
17 Sensor Type T/C-E
R/W (depends upon the
device. On Pressure
devices, this field is Read
only)
18 Line Filter 60 Hz R/W
19 Scratch Pad Scratch Test R/W
20 Last Cfg Update 04/06/2007 13:59:59 R
21