Installation Guide

© 2019 Ecolink Intelligent Technology Inc. PN TILT-ZWAVE5
Z-Wave Plus Specific Information
Z-Wave Plus is a wireless mesh network and data protocol that allows devices from
many different manufacturers to interoperate. This device implements Z-Wave Plus
functionality, Network Wide Inclusion. The following information is intended for
software engineers working on Z-Wave Plus controllers and home automation
enthusiasts to integrate the Z-Wave Plus device into their system. This product can
be operated in any Z-Wave network with other Z-Wave certified devices from other
manufacturers. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.
Z-Wave Plus Command Class Basic
For backwards compatibility with older Z-Wave Plus Controllers, the Basic
Command Class is supported in the following manner. A Basic Report of 0xFF is
Garage Open. A basic report of 0x00 is garage closed.
Manufacturer ID 0x01 4A
Product Type 0x00 05
Product ID 0x04 AA
Network Wide Inclusion
This device also supports Network Wide Inclusion such that the device can be
included into the Z-Wave network over the mesh network and not directly near the
main controller. This mode is automatically activated after regular inclusion was not
successful.
Command Class Association
This Z-Wave Plus Tilt Sensor has two Association groups of 1 nodes.
Group one Group one is the lifeline group. The garage door tilt sensor will send
Basic Reports with a value of 0x00 if the door is closed and 0xFF if the door is
opened to all nodes in group 1.
Commands Sent to Association Group One
SENSOR CONDITION
COMMAND CLASS AND VALUE
CONFIGURABLILITY
Tilt Detected
Notification report
Type: HOME SECURITY (0x07)
Event: Garage Open (0x02)
YES*
Basic Report of 0xFF
NO
Tilt Clear
Notification report
YES*
Type: HOME SECURITY (0x07)
Event: Previous Events Cleared (0x00)
Basic Report of 0x00
NO
Case Tampered
Notification report
Type: HOME SECURITY (0x07)
Event: Tampering Covering Removed
(0x03)
YES*
Wake Up Notification
YES
Case Closed
Notification report
Type: HOME SECURITY (0x07)
Event: Previous Events Cleared (0x00)
YES*
Battery Level
Battery Report of 0x01 to 0x64 is an
estimated battery level. A level of 0x00
indicates that battery should be changed
soon. A battery level of 0xFF indicates that
the battery should be changed
immediately.
NO
*Notification Reports can be configured through the Notification Set of Notification Type 0x07, and
status of: 0x00: This type of notification turned off. 0xFF: This type of notification turned on.
Z-Wave Device Class Information
This Z-Wave sensor is a Z-Wave generic Device Class of
GENERIC_TYPE_SENSOR_NOTIFICATION, and a specific device class of
SPECIFIC_TYPE_NOTIFICATION_SENSOR.
Parameter
Number
Description
Number of
Bytes
Default
Min
Max
1
Number of attempts the device
should attempt application level
retries.
1
3
0
10
2
Number of milliseconds between
application levels retries.
2
500
(0x01F4)
10
(0x0A)
5000
(0x1388)
3
The tilt angle at which the garage
door is considered closed.
Byte value 0: 10 degrees
Byte value 1: 30 degrees
Byte value 2: 50 degrees
1
0
0
2
4
The tilt angle at which the garage
door is considered opened.
Byte value 0: 30 degrees
Byte value 1: 50 degrees
Byte value 2: 70 degrees
1
0
0
2
* If you set Parameter 3 and 4 to the same byte value, Parameter 4 must be set first before Parameter
3 can be set. The opened tilt angle must be greater than the closed tilt angle