3.1 General Guidance
1. Do not install near heating and cooling sources.
2. Do not aim detector at windows due to risk of drafts.
3. Do not install outdoors.
4. Do not install where direct sunlight can strike the
unit.
5. Do not install near high-voltage electrical lines.
6. Do not install behind any obstructions.
7. Do not mount on unstable surfaces.
Figure 2. General
Guidelines
3.4 Activating and Pairing the
Detector
To
pair the detector to the Touchscreen (control panel), you must set the detector to pairing mode.
1. First set the Touchscreen (panel) to pairing mode and then the
detector
.
2. To activate, pull the activation strip that protrudes from the back of the
detector
.
3. The green LED (see Figure 1) blinks 3 times every 5 seconds (repeated up to 20 times) to
indicate
that the detector is searching for the Touchscreen (control panel).
Note: If detector pairing is not successful during the searching process
by pressing the tamper
switch
the searching process will restart.
4. Complete the pairing procedure on the Touchscreen (control panel). See
the pairing instructions in
the Touchscreen (control panel)
installation guide for details..
Note: Pairing should be performed before
installation.
After the installation a good link to the panel is displayed when the Received Signal
Strength
Indicator
(RSSI)
indicated on the panel is higher than -70dBm and the Link Quality Indicator
(LQI)
is
stronger than
250.
If the RSSI and LQI values are lower, you
must change the location of the
detector
.
3.2
Installation
Procedur
e
3.5 Rebooting the
Detector
To
reboot the detector, complete the following steps:
1. Remove the battery cover
.
2. Press and release the tamper switch (see Figure 1) for 1 to 2 seconds
.
3. Close the battery cover
.
1.
Separate detector from bracket. Figure 3.
2.
Remove the bracket.
3.
Mount bracket to wall using the center
screw holes (B) or corner screw holes (A1 &
A2). Figure 4.
4.
Install new batteries OR if batteries are
installed, remove the activation strip.
5.
Remount the detector by sliding it down
onto the bracket until a click is heard. Figure
5.
6.
The unit is ready for walk test.
3.6
Retur
n
the
Detector
to
default
mode
CAUTION! The defaulting process removes the device from the network and enables
re-pairing.
Prerequisite: Separate the detector from the bracket to remove both ba
tteries.
See Figure 6 for details
.
1. Press
and hold down the detectors tamper switch.
2. Insert one of the two batteries into the detector while observing battery polarity
.
3. Release the tamper switch within 4 seconds (the LED blinks 3 times every
5 seconds).
4. To re-pair the detector, follow the instructions in section
3.4.
Note: It is recommended to wait about 1 minute after battery removal, before inserting the new
ba
tter
y
.
3.7
W
alk
T
esting
3.3
Replacing
the
Batteries
Walk across the far end of coverage pattern in both directions. The LED should light for 2-3
seconds
each time your motion is detected.
1. Press upward to separate the detector
from
the bracket.
2. Replace the ba
tteries.
3. Put back the detector on the bracket.
Note: It is recommended to wait
approximately 1 minute after battery
removal before inserting the new
battery.
CAUTION! Risk of explosion if
battery is replace by an incorrect
type. Dispose of used battery
according to the manufacturers
instructions.
Important!
Instruct the user to walk test at
least once a week to verify proper function of
the detector
.
Note:
After battery insertion or closing the
cover (which results in closing the tamper
switch)the LED
flashes for 2 minutes and
the detector goes into walk-test mode for
15 minutes. In walk test mode
the LED
lights
for every motion detected. After 15 minutes
the detector automatically enters normal
mode
i n which the LED
will not blink after
detection.
Figure 7 Coverage Pattern Walk-Test