User's Manual
© 2015 Ecolink Intelligent Technology Inc. PN PIR-ZWAVE2 R1.03
Sensor Case Removed
Notification Report of Home Security
(0x07), Tampering product cover
removed (0x03)
1
0x00: This type of notification turned
off
0xFF: This type of notification turned
on
Sensor Case Fastened
Wake-Up Notification
1
Yes via Wake-Up Notification
Command Class
Battery Level Dipped Below 2.6v
Notification Report of Power
Management (0x08), Replace
battery now (0x0B)
1
Yes via Notification Set of
notificationType (0x08) and status of
0x00: This type of notification turned
off
0xFF: This type of notification turned
on
Wake-Up Notification
The sensor will wake up every so often and when the case is closed to send a Wake-Up Notification to allow the life line master node controller that the sensor is
now available for any queued messages that the controller may have for the sensor. The time between Wake-Up Notifications can be configured with the Wake-
Up Notification command class to be between 1 hour and 1 week with interval steps of 200 seconds.
Configuration
The sensor has two configuration parameters. Parameter 1 configures the sensor to send or not send Basic Set commands of 0x00 to nodes in Association group
2 turning the devices off when the sensor is in a restored state i.e. motion not detected. By default the sensor does NOT send Basic Set commands of 0x00.
Parameter 2 configures the sensor to either to send or not to send Sensor Binary Report commands to Association Group 1 when the sensor is faulted and
restored. If the controller is fully compatible with the Notification Command Class thereby making the Sensor Binary Reports redundant, the controller can
disable the Sensor Binary Report Commands completely. The following table shows the values to enable and disable the two configuration parameters.
Configuration Set Values
Effect
Parameter Number: 1
Size: 1
Configuration Value: 0x00
(Default) Sensor does NOT send Basic Sets to Node
IDs in Association Group 2 when the sensor is
restored ( i.e. Motion Not Detected ).
Parameter Number: 1
Size: 1
Configuration Value: 0xFF
Sensor sends Basic Sets of 0x00 to nodes in
Association Group2 when sensor is restored.