Product Specs
Table Of Contents
Page 7 of 10
Configuration Command Class
Parameter
Name
Description
Default
Min
Max
1
Swap Siren and Chime Sound
mapping.
0: A Basic Set of 0xFF starts playing Siren.
1: A Basic Set of 0xFF starts playing Chime.
0
0
1
2
Periodic heartbeats
The number of seconds between automatic Heartbeat Notifications.
3600
120
86400
3
Encapsulate Unsolicited
Notifications/Reports in
Supervision
Encapsulate Unsolicited Notifications in Supervision Get requests.
0: Disabled
1: Enabled
0
0
1
4
Sound Volume
Sound volume as a percentage for non-emergency sounds.
100
0
100
5
Total Number of Sounds
Available
Read only
100
0
100
Notification Types
The Chime+Siren Implements two notification types for Power Management and System level notifications which are sent unsolicited to the Lifeline Association
Group 1.
Power Management (0x08)
Name
Value
Description
Mains status
0x02
AC mains disconnected
Mains status
0x03
AC mains re-connected
Battery load status
0x0C
Battery is charging
Battery level status
0x0D
Battery is fully charged