Product Specs

Page 4 of 10
Z-Wave Device Class and Command Class Information
This Z-Wave sensor is a Z-Wave generic Device Class of GENERIC_TYPE_AV_CONTROL_POINT (0x03), and a specific device class of SPECIFIC_TYPE_SOUND_SWITCH (0x01).
Manufacturer Specific
Manufacturer ID: MFG_ID_ECOLINK
Product Type:
0x0007
Product ID:
0x3975
Factory Default
To restore the device back to factory settings and remove it from any Z-Wave network. Remove the device from power-outlet. Hold the Add/Test button while
re-inserting siren into power-outlet and continue to hold Add/Test button for 10 seconds. During the 10 seconds of continuing to hold the Add/Test button the
green LED with flash, and after 10 seconds the red LED will come on solid for 1 second indicating that the factory default of the device has been successful, and
the device is ready to add back into a Z-Wave network.
Association
This sensor has one Association group (Lifeline) with only one node for that group. Group one is a lifeline group who will receive unsolicited messages relating to
AC and Battery power notifications, and Device Reset Notifications.
Network Wide Inclusion
This sensor also supports Network Wide Inclusion such that the Sensor can be included into the Z-Wave network over the mesh network and not directly near
the main controller. This mode is automatically activated after regular inclusion was not successful.
Test Mode
While the device is included into a network, the learn button can be used to test the Z-Wave connection. It will transmit a System Heartbeat notification to the
node configured in Association Group 1. If the device receives an ACK + Supervision, the Green LED will turn on solid, otherwise the Red LED will turn on solid,
and the device will then send a Wake-Up Notification.