User's Manual

6 | P a g e
Any state/command pair not specified in the following figure will not cause any action:
The Garage Door Controller will not respond to Set Commands if any of the following issues are detected:
- No tilt sensor is paired
- Tilt sensor is tampered
- Tilt sensor counter is out of sync
- Tilt sensor is lost (Garage Door Controller hasn’t heard from the tilt sensor in 2 hours)
- Tilt sensor is in the wrong state
A timeout error will occur if the tilt sensor does not change states after an unattended open/close command
is executed. After a timeout error occurs, Barrier Operator Set open/close commands will be ignored until
the garage door operator is manually triggered by the user and the tilt sensor changes states.
Whenever the Garage Door Controller receives and ignores a Barrier Operator Set Command, the Garage
Door Controller’s warning light will blink 3 times.
The “Stopped” state is removed because the tilt sensor only reports open or closed: there is no way to
confidently know that the garage door is stopped.
Barrier Operator Signal Set Commands can be sent but will not cause any action to the audible or visual
subsystems.
Configuration
The Garage Door Controller supports the six configuration parameters listed below.
1. Unattended Wait Period
Description
Unattended close operation wait period in seconds.
Size
1
Format
Unsigned Integer