User's Manual

5 | P a g e
Mapping of the Basic Command Class
The Garage Door Controller has the Basic Command Class mapped to the Barrier Operator Command Class
such that a Basic Set of a value is the equivalent of a Barrier Operator Set of a target value. A Barrier Operator
Report with a state of 0x00 will map to a Basic Report with a current value of 0x00. And a Barrier Operator
Report with a state > 0x00 will map to a Basic Report with a current value of 0xFF.
Z-Wave Command Classes
Command Class
Version
Secured via S2
Z-Wave Plus Info
2
Association
2
√
Association Group Info
3
√
Barrier Operator
1
√
Configuration
4
√
Device Reset Locally
1
√
Firmware Update Metadata
5
√
Indicator
3
√
Manufacturer Specific
2
√
Multichannel Association
3
√
Multilevel Sensor
11
√
Notification
8
√
Power Level
1
√
Security 2
1
Security 0
1
Supervision
1
Transport Service
2
Version
3
√
Association
The Garage Door Controller supports one Association group: the “Lifeline” group which can have one node in
the group. All unsolicited Z-Wave messages are transmitted to the node in the Lifeline group such as Barrier
Operator, Device Reset Locally notifications, Indicator, and Notification.
Barrier Operator
The Garage Door Controller supports the Barrier Operator Command Class which is used to control and query
the status of the garage door. A Barrier Operator Set Command of 0xFF will initiate an unattended open, and
a command of 0x00 will initiate an unattended close. Before an unattended close command is executed, it
will have a minimum wait period of 5 seconds, during which the warning light will flash, and the speaker will
beep. If the state of the garage door changes or the garage door is active during this unattended wait period,
the original close command will be ignored.