User's Manual
the audio detector and smoke alarms after battery installation to confirm proper operation
LEARN BUTTON
6” MAX
TAMPER SWITCH
MARKINGS TO LINE
UP WITH EXISTING SMOKE DETECTOR
BATT
IMAGE 1: ENROLLING / TEST / TAMPER BUTTON IMAGE 2: INSTALLATION DISTANCE IMAGE 3: SIDE MARKINGS
Z-Wave Specific Information
Z-Wave is a wireless mesh network and data protocol that allows devices from many different manufacturers to
interoperate. This device implements Z-Wave+ functionality, Network Wide Inclusion, and Explorer frames. This device is
asleep most of the time but can respond to queries on a Wake Up Notification; however for test purposes, the device
will stay awake while tampered for testing Z-Wave command class functionality. The following information is intended
for software engineers working on Z-Wave controllers and home automation enthusiasts to integrate the Z-Wave
FireFighter™ into their system.
Device Classes
Generic Device Class
GENERIC_TYPE_SENSOR_NOTIFICATION
Specific Device Class
SPECIFIC_TYPE_NOTIFICATION_SENSOR
Command Classes
COMMAND_CLASS_ZWAVEPLUS_INFO
v2
COMMAND_CLASS_VERSION
v2
COMMAND_CLASS_MANUFACTURER_SPECIFIC
v2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
v1
COMMAND_CLASS_POWERLEVEL
v1
COMMAND_CLASS_BATTERY
v1
COMMAND_CLASS_SENSOR_MULTILEVEL
v7
COMMAND_CLASS_NOTIFICATION_V5
v5
COMMAND_CLASS_ASSOCIATION
v2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
v1
COMMAND_CLASS_WAKE_UP
v2
COMMAND_CLASS_FIRMWARE_UPDATE_MD
v2
Manufacturer ID
MFG_ID_ECOLINK ( 0x014A )
Product Type
0x05
Product ID
0x0F