Installation Guide
Table Of Contents
- Product Overview
- The remote temperature sensor is wall mountable remote sensor for use with any ClearSky™ compatible system. This sensor is ideal for remotely monitoring room temperature and reporting back to control panel or thermostat. The CS-502 also supports ext...
- Features
- Specifications
- Package contents
- Installation Instructions
- Pairing
- To pair the sensor, set your ClearSky Compatible Controller into sensor learn mode. Refer to your specific ClearSky Compatible Controller instruction manual for details on these menus.
- On the temperature sensor, locate the learn button above the external probe connector. Initiate pairing by pressing the the learn button. Repeat as needed by the ClearSky Compatible Controller.
- Unpairing
- Testing
- FCC Compliance Statement
© 2020 Ecolink Intelligent Technology Inc. PN CS-502
Product Overview
The remote temperature sensor is wall mountable remote sensor for use
with any ClearSky™ compatible system. This sensor is ideal for remotely
monitoring room temperature and reporting back to control panel or
thermostat. The CS-502 also supports external NTC 10K ohm Type 2 probes.
Features
• Quick installation
• Compatible with any ClearSky™ compatible system
• Monitor temperatures remotely
• Alerts you of a change in temperature
• Encrypted protocol – reliable and secure
Specifications
• For indoor use only
• Operating frequency: 345 MHz
• Operating temperature: 0° – 49°C, 32° – 120°F
• Operating humidity 5-95% RH non-condensing
• Battery: 2x AAA 1.5V DC batteries
• Battery Life: up to 8 years
• Detection of standing water within 1 second across gold
probes
• Temperage Range (onboard thermistor): 0° – 49°C
o With External 10k ohm
• External Probe Input fits 24-18 AWG wires.
Package contents
• 1 x Remote Temperature sensor (with AAA batteries)
• 1 x Double Sided Adhesive Tape
• 2 x Mounting Screws
• 1 x Installation Manual
Installation Instructions
(1) Identify location for Remote Temperature Sensor.
(2) Pair the sensor to the ClearSky™ compatible hub. Follow pairing
instructions in the next section.
(3) If using an external probe, strip the wire off 7 to 9 mm and insert
them into the external probe connector. See Figure 1
(4) Move the flip switch to the “external probe” position.
External Probe
Connector
Flip Switch
Down = External Probe
Up = Onboard