User Manual

If successfully enrolled the status module will beep.
Press the learn button on the bridge to exit this mode.
At this point you can replace the battery cover of the status module.
At this point, one of the bottom LEDs (open or closed) may be illuminated. This is showing the status of
the sensor you have enrolled but have not yet installed.
Installing and testing your sensors
Your sensors come in two parts, the actual transmitter and the magnet.
You must choose a location on the door or window such that when installed
the maximum distance between the sensor and the magnet is 0.5 inches.
It is preferred (but not mandatory) that the sensor be mounted on the frame
and the magnet on the door.
Double sided tape is included with your sensor to mount the devices.
Ensure the surface is clean and dry.
Apply the tape to the sensor then press firmly into the designated location
on the door or window. Hold for 10 seconds. Repeat for the magnet.
Once your sensor is correctly installed, open and close the door or window. As you open you should
hear the bridge beep. Note the bridge will not beep when you close the door.
Repeat these steps until all your sensors are installed.
Using the status module to test
If you are in a part of the home where you cannot hear the bridge, you can use the status module to
help you test the devices you are installing.
To do so you must make sure all the devices that are enrolled in the system are in the closed state. So if
already mounted the door and window must be closed, if not mounted the magnets must be touching
the sensor.
You can confirm this as the status module will illuminate the green (closed) LED.
Then simply bring the status module with you as you install your device, when you open and close the
door you have installed the sensor on, the status module will illuminate the open (Red) or closed (green)
light accordingly.
Mount the status module
Once the installation is complete, mount the wall bracket of the status module to the desired location
and install the status module. The status module is designed to be off, when motion within 2-3 ft is
detected directly in front of it, it will turn on, and request status from the bridge. After a few minutes of
not detecting motion it will turn off.
If the open LED (red) flashes, that indicates that it has lost communication to the bridge. If this condition
persist, you may have to relocate the status module or relocate the Ecolink Bridge.