User Manual
Patient Safeguard System – Dispenser Beacon User’s Guide UltraClenz, LLC
Page 8
will change to the warning state. The badge will produce 3 quick beep tones with the second tone being lower in
pitch than the first or third tones. This indicates successful communications between the badge and the bed
beacon located within the patient zone. The badge’s red LED will then blink about once every 1.5 seconds.
Immediately after changing to the warning state, the badge will produce a rapid burst of 4 tones with each having
a different pitch. This will be repeated 4 more times over the next 20 seconds and will indicate to the HCW that
they must wash/sanitize their hands immediately.
A HCW may not go from one patient zone to another without washing/sanitizing in-between. While a HCW is in a
patient zone, their badge will be in the cautionary state. When they leave the patient zone, their badge will remain
in the cautionary state for up to 5 minutes beyond which time their badge will automatically change to the warning
state or until they wash/sanitize at which time their badge will then change to the sanitary state. If the HCW
leaves a patient zone and then enters a different patient zone without first interacting with a soap/sanitizer
dispenser, the badge will change from the cautionary state to the warning state. The badge will produce 3 quick
beep tones with the second tone being lower in pitch than the first or third tones. This indicates successful
communications between the badge and the bed beacon located within the patient zone. The badge’s red LED
will then blink about once every 1.5 seconds. Immediately after changing to the warning state, the badge will
produce a rapid burst of 4 tones with each having a different pitch. This will be repeated 4 more times over the
next 20 seconds and will indicate to the HCW that they must wash/sanitize their hands immediately.