Step 3 Install Gearbox back into the Dispenser
To reinstall the touch-free gearbox, place the bottom 2 pivot points into the chassis base and pivot the top
towards the chassis until the touch-free gearbox latches and clicks into place. Close the cover. The finished
installation should look like Figure 9 below.
Figure 9 Complete Installation
Testing the Tag
This procedure will require a dispenser with the Tag installed, a hub (optional), a USB to RS485 Network Interface
Kit (KIT1101-00), and a gateway attached to a computer running a Terminal Emulation program.
Step 1 Setting up Test Equipment
For instruction on how to install and configure the USB to RS485 Network Interface Kit, please refer to DOC1000.
Insert the RJ-11 connector, located on the end of the serial cable, into the RS-485 port on the back of the
Gateway as shown in figure 10. The other end of the serial cable will be inserted into the RS-485 Data port on
the USB to RS485 Network Interface adapter.
Figure 10 Location of serial connection in back of Gateway
Insert the USB cable into a USB port on computer. The other end of the USB cable will be inserted into the RS-
485 Data port on the USB to RS485 Network Interface adapter.
Step 2 Configuring Terminal Emulation Software (HyperTeminal)
For instructions on how to configure Terminal Emulation Software (HyperTerminal), please refer to DOC1038
(WiNET Gateway User Guide). With communications established between Gateway and computer, start a
terminal session. Press G [enter] until the Gateway events are ON. Press M [enter] until the Monitor Events are
OFF.