EASYNET GATEWAY EN USER AND INSTALLATION MANUAL MODEL: SAT CONTACT:
EN User and installer's manual Contents 1. General information ............................................................................................................................................................... 4 1.1. Safety considerations ............................................................................................................................................................. 4 1.2. Recycling ..................................................................................
EN User and installer's manual 1. General information ▪ To obtain the most performance from your EASYNET GATEWAY device, we recommend that you read this manual carefully before you use it. ▪ Keep this manual for future reference. Thank you for purchasing an ECOFOREST product. This manual contains information about the overall operation of the unit and on how to use its different functionalities.
EN User and installer's manual 1.2. Recycling ▪ This device should not be treated as household waste. ▪ At the end of its life it should be disposed of as common municipal waste, in an environmentally friendly manner and in accordance with local regulations. 2. Description 2.1. EASYNET GATEWAY device The EASYNET GATEWAY has been designed to establish different connection paths between your ECOFOREST device and any type of device that has a web browser, such as a mobile phone, a tablet, a PC, etc.
EN User and installer's manual 4 8 2 3 1 6 7 5 Figure 2.2. EASYNET web interface main screen. ECOFOREST heat pump (example). Main screen fields 1. CENTRAL INFORMATION BAR. This displays certain basic information about the device. 2. OPERATION PROGRAM. This displays the device’s current operating program. 3. OPERATION MODE. This displays the active operation modes of the device. 4. ALARM CODE. This displays the current alarm status of the device. 5.
EN User and installer's manual 3. Installation Before installing EASYNET GATEWAY, turn off and disconnect the power supply to the ECOFOREST ▪ DANGER! device you intend to connect. Otherwise, severe injury may result from electrocution. To install the EASYNET GATEWAY, follow the steps below: 1. Place the communication module inside the ECOFOREST device, in a dry place that does not interfere with the normal operation of the device.
EN User and installer's manual 6. Check that the EASYNET GATEWAY communicates correctly with the ECOFOREST device. The device has a LED that indicates different connection statuses. PULSE FREQUENCY STATUS Pulse 10s on / 10s off Establishing communication with ECOFOREST device 3 pulses on / off of variable duration Configuring EASYNET GATEWAY Pulse 1s on / 1s off Device connected to ECOFOREST device Continuous on pulse Communication failure with ECOFOREST device Table 3.2.
EN User and installer's manual GATEWAY EASYNET ETHERNET Figure 4.1. DIRECT-ETHERNET mode connection scheme. Direct cable access (example). NOTE ▪ The DIRECT-ETHERNET mode always remains enabled by default. ▪ This configuration does not allow remote access via the Internet. 4.2. AP-WiFi ORIGINAL / CUSTOM AP-WiFi mode This lets you access the ECOFOREST device from your device (mobile phone, tablet, PC, etc.
EN User and installer's manual AP WiFi GATEWAY EASYNET Figure 4.2. AP-WiFi mode connection scheme. Direct access by WiFi (example). NOTE ▪ The wireless network generated by the GATEWAY does not have an internet connection. ▪ Some devices, such as mobile phones, can block access to networks that do not have an internet connection. Check your device's settings to allow connection to networks that do not have an internet connection.
EN User and installer's manual GATEWAY EASYNET 3G / 4G INTERNET ETHERNET ETHERNET Figure 4.4. LAN-ETHERNET mode connection scheme. Remote access via the Internet (example). ▪ The LAN-ETHERNET settings are enabled at the factory by default. If it has been disabled, try logging in using the current settings to reconfigure it. If this does not work, contact your service representative.
EN User and installer's manual WiFi LOCAL WiFi LOCAL GATEWAY EASYNET ETHERNET Figure 4.5. LAN-WiFi mode connection scheme. Access through the local network (example). WiFi LOCAL GATEWAY EASYNET 3G / 4G INTERNET ETHERNET Figure 4.6. LAN-WiFi mode connection scheme. Remote access via the Internet (example). ▪ If the connection test is unsuccessful, this may be due to the wireless signal generated by the router being too weak.
EN User and installer's manual 4.5. Connection mode settings To change the settings of the GATEWAY EASYNET connection type, follow the steps below: 1. Access the EASYNET web interface via one of the enabled connection modes. 2. Access the connection settings screen by following the steps below 3. Select the desired connection mode. 4. Refer to the EASYNET web interface access information of the enabled connections. ▪ WiFi: Name (SSID) of the enabled wireless local network or wireless access point.
EN User and installer's manual 6. Manufacturer's warranty ECOFOREST is liable for lack of conformity of the product or its spare parts, in compliance with the current regulations of the country where the product is purchased. The warranty is only valid in the country where the product is purchased. Conditions and validity of the warranty For this warranty to be considered valid the following conditions must be verified.
ECOFOREST GEOTERMIA, S.L. Parque Empresarial Porto do Molle l Rúa das Pontes, 25 l 36350 – Nigrán – Pontevedra.- (Spain) Tel.: +34 986 262 184 http://www.ecoforest.es Gateway EasyNet Gen2 USER AND INSTALLATION manual Version 00E/2022 The manufacturer reserves the right to make any necessary changes to the contents of this manual without prior notice.