EcoFlow Smart Generator User Manual
Disclaimer Users are expected to read this User Manual carefully and ensure they have fully understood the content before using this product. Please keep this User Manual for future reference. Any incorrect usage may result in severe injury to the user or others, damage to the product or loss of property.
Contents 1. Safety Guidelines 1 1.1 Safety Warning 1 1.2 Safety Instructions 1 1.3 Important Labels 2 2. Quick Start 3 2.1 Appearance Description 3 2.2 Introduction to the Icons on the Display Screen 5 2.3 Before You Use the Product 6 2.4 Using the Product 9 --2.4.1 Startup 9 --2.4.2 Turning Off 10 --2.4.3 AC Connections 10 --2.4.4 DC Charging 11 2.4.4.1 Charging the DELTA Max or the DELTA Pro 11 2.4.4.
1. Safety Guidelines 1.1 Safety Warning The safety of you and others, as well as of property are of the primary importance. Please carefully read the extremely important safety warnings we have written in the User Manual and the sticker of the generator set. This is to remind you of the potential dangers which may harm you and others. Before each safety warning is a symbol and one of the three following words: danger, warning or caution.
1.3 Important Labels Please refer the following stickers carefully before starting to use the product. ! WARNING Read the owner's manual and all labels before operating. Only operate in well-ventilated areas. Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. Tampering with this CO alarm system will cause Carbon Monoxide poisoning! Electrocution can occur if generator is used in rain, snow, or near water.
2. Quick Start 2.
*AC socket adapts according to local standards.
2.2 Introduction to the Icons on the Display Screen Wi-Fi Status Total Run Time Remaining Power Percentage Remaining Running Time Output Power Rechargeable Battery Fault Alert Low Temperature Alert High-Temperature Alert Error Code Carbon Monoxide Alert ECO Eco Mode Communication Connection Output Overload Alert AC Output DC Output Remaining Power Percentage: If the remaining fuel level is lower than 600 mL/20.3 oz., the indicator will be at 0% charge and flash to warn you.
2.3 Before You Use the Product Refueling Danger Please read the Safety Guidelines carefully before refueling as fuel is inflammable and toxic. Do not overfill the fuel tank, as fuel may expand and spill out when the fuel tank warms up. Be sure to tightly close the fuel cap after refueling. Open fuel cap Caution Red Indicator Clean away the residual fuel with a clean and soft cloth after refueling to avoid damage to the rubber shell.
Add Generator Engine Oil Caution There is no engine oil in the generator when delivered from the factory. Do not start up the generator until after adding sufficient engine oil. Do not tilt the generator when adding engine oil, to prevent damage to the generator due to adding excessive oil. 1. Place the generator on a level plane. 2. Turn the maintain cover knob to and take off the maintenance cover. Removing the maintenance cover 3. Unscrew the lid and oil dipstick. 4.
Checking Before Use Warning Please check the following components carefully each time before using the generator. a) Check the fuel level Take off the fuel cap and check the fuel level. Inject more fuel into the tank if the fuel level is too low. b) Check the engine oil level Make sure there are no engine oil leaks. Check the engine oil level. If the oil level is low, the engine oil alarm system may shut off the engine. 1. Unscrew the lid, take out the oil dipstick and wipe it clean. 2.
2.4 Using the Product Danger Read the Safety Guidelines before use. Do not use the generator in a closed space as the exhaust fumes may result in a loss of consciousness or even death. Use it in a well-ventilated place. Do not connect the AC Output Socket with any electrical equipment before starting the generator. Tips: The generator is used at 5 ℉-104 ℉(-15 ℃—40 ℃).
2.4.2 Turning off To turn the engine off in an emergency, turn the engine switch to the “OFF” position. In any other circumstances, please follow the below steps. 1. Switch off all electrical equipment and disconnect them from the generator. 2. There are four methods to turn off the generator: a) Using the Engine Switch: Turn the Engine Switch to “OFF” to turn off the generator. b) Using the Electric Start button: Press and hold the Electric Start button for 2 seconds to stop the engine.
2.4.4 DC Charging 2.4.4.1 Charging the DELTA Max or the DELTA Pro 1. Turn the fuel cap breather valve knob to "ON" ① (see Step 1 in paragraph 2.4.1). 2. Turn the Engine Switch to "ON" (see Step 2 in paragraph 2.4.1). 3. Connect with the DELTA Max ① or the DELTA Pro ② through the 5m/ 16.4ft Extra Battery Connection Cable*. 4. If the remaining power of the DELTA Max or the Extra Battery Connection Cable DELTA Pro falls to the lower limit, it will send a request to the generator to recharge.
2.4.4.2 Charging the DELTA Max Extra Battery Pack or the DELTA Pro Extra Battery Pack 1. Turn the fuel cap breather valve knob to "ON" (see Step 1 in paragraph 2.4.1). 2. Turn the Engine Switch to "ON" (see Step 2 in paragraph 2.4.1). 3. Connect to the DELTA Max Extra Battery ③ or DELTA Pro Extra Battery ④ with the 5m/ 16.4ft Extra Battery Connection Cable. 4. Switch on the DELTA Max Extra Battery or DELTA Pro Extra Battery and it will send a request to the generator to recharge.
2.4.6 Application Range Please make sure that the total load of the generator is within the rated range before using the generator, or otherwise the generator may be damaged. Application Power Factor 1 0.8–0.95 0.4–0.75 (Efficiency 0.
3. Maintenance and Servicing Proper maintenance and servicing is essential to ensure safe, economical and reliable usage. This also helps minimize your environmental impact. You must regularly check and service your generator to keep it in optimal condition based on the schedule below.
3.1 Checking the Spark Plug The spark plug is an important part of the generator and must be checked regularly. 1. Turn the maintain cover knob to and take off the maintenance cover. 2. Take off the spark plug cap. 3. Use the spark plug socket and revolve it counterclockwise to remove the spark plug. 4. Check for any fading in color and remove any carbon deposits. The porcelain center around the spark plug center electrode should be moderately light brown if it is in good condition.
3.3 Replacing the Engine Oil Warning Do not drain the engine oil immediately after the generator is switched off. The oil temperature will be very high. Please take care not to get scalded when draining the oil. 1. Place the generator on a level plane, start it up and keep it running for several minutes to increase its temperature. Then turn it off. Turn the Engine Switch and the fuel cap breather knob to "OFF". and take off the maintenance cover. 2. Turn the maintain cover knob to 3.
3.5 Fuel Filter Strainer 1. Take off the fuel cap and fuel filter screen. Warning 2. Clean the fuel filter 3. Wipe the filter screen and screen with fuel. place it back into the fuel. 4. Reinstall the fuel cap. Never use fuel in any place near smoke or flames. Caution Be sure to tighten the fuel cap. 3.6 Muffler 1. Unscrew the bolts. 2. Take off the muffler cap, muffler block and spark plug arrestor. 3.
4. Storage and Transportation If you plan to place this generator into long-term storage, you need to take some storage measures to prevent premature aging of the generator. 4.1 Draining the Fuel 1. Turn the Engine Switch to "OFF". 2. Open the fuel cap, take out the fuel filter screen, drain all the fuel from the fuel tank into a temporary fuel tank and reinstall the fuel cap. 3. Start the generator. The remaining fuel will be used up in about 20 minutes.
4.4 Use after storage If the generator is stored with fuel in the fuel tank and carburetor, conduct servicing as required in the table below before using again.
5. Faults and Troubleshooting Errors Content of Tips Error Type Icon flashes Fuel system Unable to start Oil Alert Indicator stays on Recovery Methods Turn the fuel cap breather valve knob to "ON" The Engine Switch is in the OFF position Turn the Engine Switch to "ON" There is no fuel left Refueling The generator set was not properly prepared for storage, or the gasoline was not evacuated, or the quality of injected fuel was poor.
6. Parameters and Specifications Complete machine Generator Engine Length × width × height 23.5×11.7×18.7 in/597×296×475 mm Net weight 64.6 lbs/29.3 kg Type Inverter generator Frequency 50 Hz Rated voltage 230 V Rated power 1800 W (peak value 1900 W) Power factor 1 DC output voltage 42–58.8 V Maximum DC output current 32 A Engine model R80-i Engine type Single cylinder, four-stroke, forced-air cooling, overhead valve Engine displacement 79.
8.