SDS

4. ANTI-LEAKAGE PERFORMANCE
No.
Test Item Test Method (IEC Standard) Sample QTY.
Standard Value
(Initially)
1
High Temperature
Anti-leakage Test
Store the battery (batteries) under an
environmental condition of
Temp.60±2℃ and RH: 90±5% for
certain days, then put
them under normal
atmospheric temperature for 4~24 hours.
20 pcs
No leakage
within 40
days
5. SECURITY CHARACTERISTICS (Environment Temp.20±2, RH.55±20%)
No.
Security Test Item Test Method
Sample QTY.
Specification Standard
1
Over discharge
Anti-leakage Test
IEC Standard
5 pcs No explosion
2 External Short-Circuit
IEC Standard
5 pcs No explosion
3 Improper Installation
IEC Standard
5 groups No explosion
4 Free Drop Test IEC Standard
5 pcs No explosion
6. USAGE GUIDE (Please refer to IEC60086-5 for detailed safety and
storage specifications)
(1) Insert batteries correctly with regard to the polarities (“+”/”-”) marked on the battery and the
electrical appliances;
(2) Do not short-circuit, recharge, heat, disassemble the battery, or dispose of in fire;
(3) Do not mix use old batteries with new ones, or mix use batteries of different types or brands;
(4) Exhausted batteries should be immediately removed from the equipment;
(5) Keep the batteries away from small children; do not let the child remove/ replace batteries
without monitoring from adults.
(6) Storage condition of the batteries shall be Temperature: 15℃~25℃ (no higher than 30℃),
while extremely damp environment beyond RH: 40%~90% shall also be avoided. Naked
battery is recommended to be stored after being labeled.