Replacement Part List

Table Of Contents
1414
EN
Troubleshooting
Indicator Problem
Resume normal operation by removing
the electrical device connected to the
USB-A port.
Resume normal operation by removing
the electrical device connected to the
USB-C port.
After the product cools down, it will
resume normal operation automatically.
Charging can be resumed automatically
after the battery cools down.
The power supply can be resumed
automatically after the battery cools
down.
Charging can be resumed automatically
after battery temperature rises above 5°C
(41°F).
The power supply can be resumed
automatically after the battery temperature
rises above -12°C (10°F).
Please confirm whether the fan inlet and
outlet are blocked, if not, normal operation
will be resumed automatically after the
product temperature drops.
Normal operation will be resumed
automatically after the product is used at
optimum environmental temperatures.
Please check if the fan is blocked by
foreign materials.
Normal operation will be resumed
automatically after you remove the
overloaded device and restart the
product.
Electrical appliances should be used
within rated power.
(Refer to X-Boost instructions to get more
details about power limitations).
Solution
The product will resume normal operation
automatically after you remove the device
connected to the car charger.
After the product cools down, it will resume
normal operation automatically.
Contact EcoFlow customer service.
USB-A Overload
Protection
(Flashing)
(Flashing)
(Flashing)
(Flashing)
(Flashing)
(Flashing)
(Flashing)
(Flashing)
(Flashing)
(Flashing)
(Flashing)
(Stays on)
USB-C Overload
Protection
(Flashing)
(Flashing)
USB-C High
Temperature Protection
High Temperature
Charge Protection
High Temperature
Discharge Protection
Low Temperature
Charge Protection
Low Temperature
Discharge Protection
AC Output
Overload Protection
AC High
Temperature Protection
AC Low
Temperature Protection
Fan Blockage
Car Charger
Overload Protection
Car Charger High
Temperature Protection
Battery Failure
If the alarm prompt shows on the product LCD screen during use and does not disappear
after a restart, please stop using it immediately (do not try to charge or discharge). If you