Technical information

30.1
Decommissioning the boiler
When decommissioning the boiler,
precautions should be taken to avoid frost
damage. Therefore it is essential that both
the boiler and the central heating system
are completely drained down.
To do this remove the front casing and
connect a hose to the central heating drain
point. The system should be vented by
opening the DHW valve and /or the manual
air vent on the central heating circuit.
Tag the boiler “DO NOT USE SYSTEM
DRAINED” and remove the fuse at the
isolating switch.